DK424 Installation
Reserve Power Installation
5-42
Strata DK I&M 6/00
Right Side View
Loosen bottom two cover
screws to remove cover
Bottom
Cabinet
RFMFI
+
–
BATT
L
N
AC120V
FG
RCCB
(Shown with cover off)
Loosen top two cover
screws to remove cover
RCCB1 or RCCB2
(Shown with cover on)
Side View of RCCB
Conduit Holes to
1/2 Inch
(Tradesize)
Conduit
To RBDB or RBDB2
(Battery Distribution Box)
Battery Wires
(12-AWG minimum)
24 AMPS Max
AC Power Wire
(14-AWG minimum)
11.5 AMPS Max (RCCB1)
17.5 AMPS Max (RCCB2)
RCCB1 (3~6 Cabinets)
or
RCCB2 (7 cabinets)
1473
Third cord is on
RCCB2 only
Fuse Ratings
AC:
BAT:
F1~F3, 250V, 12A
F4~F6, 250V, 15A
Figure 5-26 Conduit Connection Box (RCCB)
(Required to Floor Mount Three or More DK424 Cabinets Only)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...