DK424i Installation
Step 5: Install Reserve Power
7-34
Strata DK I&M 6/00
Bolt Cabinets to Wooden Floor
1. Mount the DK424i Base Cabinet on Floor
and
2. Position the Base Cabinet at the selected
installation location.
3. Mark the floor where holes will be drilled.
Move the Base Cabinet prior to drilling.
Note
Cover the Base Cabinet with a drop
cloth to protect the power equipment
from dust created during drilling.
4. Drill pilot holes to make insertion of 3/8
inch lag bolts easier, and to prevent
splitting of wood flooring.
5. Move the Base Cabinet into position on the
equipment room floor.
6. Secure the Base Cabinet to the floor using lag bolts, lock washers, and flat washers
Bolt Cabinets to Computer Room Floor
1. Mount the DK424i Base Cabinet on Floor Mount Fixtures (BIMF). See
and
2. Position the Base Cabinet at the selected installation location.
3. Mark the floor where holes will be drilled. Move the Base Cabinet prior to drilling.
Note
Cover the Base Cabinet with a drop cloth to protect the power equipment from dust
created during drilling.
4. Drill holes through tile for 3/8-inch threaded rods.
5. After the tiles have been drilled, insert threaded rods through the holes in the tile and mark the
concrete floor directly beneath the holes in the tiles.
6. Remove the tiles. Use a hammer drill to make holes for 3/8-inch bolt anchors.
7. Install the bolt anchors with plugs in the
drilled holes.
8. Using the driving tool and a hammer, drive
each bolt anchor into the floor.
9. Screw threaded rods into each bolt anchor.
10. Install a hex nut, lock washer, and flat
washer on each threaded rod. Screw the
nuts down far enough to allow floor tiles
to be replaced over the threaded rods.
11. Replace tiles over threaded rods in their
original positions on the floor.
12. Reach under the tiles, and screw the hex
nuts upward until the flat washers are
touching the bottom of the tile.
Wooden
Floor
BFIF
(Floor
mount
fixture)
Base
Cabinet
Bolt
Lockwasher
1468
Figure 7-20 Installation on Wooden Floor
Floor Tiles
Lead Anchors
Concrete
Flat Washer
Lock Washer
Hex Nut
BFIF
(Floor
mount
fixture)
Bottom
Cabinet
1469
Figure 7-21 Installation on Computer Room Floor
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...