Universal Slot PCBs
RDTU – T1 Interface Unit
Strata DK I&M 6/00
9-49
Universal Slot PCBs
RSIU, RSIS, RMDS – RS-232/Modem Interface Unit
System:
DK424, DK424i
Circuits per PCB:
four interface ports
Interfaces with:
SMDI or Toshiba Proprietary RS-232 voice mail
ACD SMIS computer
SMDR printer or SMDR call accounting machine
DKi Admin/DKi Backup PC or maintenance terminal (locally or remotely)
Open-architecture application computer system–receives ANI, DNIS or CLID digits from
the DK424 and DK424i on ACD calls
Older Version(s):
none
The RSIU is a standard plug-in type PCB that must be installed into the first universal slot of the
DK424 or DK424i base cabinet. The RSIU PCB provides one standard RS-232 port (modular
jack) when ordered from the factory; this port can be configured in system programming to
support any one of the hardware options listed above.
The RSIU can be equipped with up to three more optional RS-232 ports (total of four RS-232
ports) or with two optional RS-232 ports and one modem port (total of three RS-232 ports and one
modem port). The optional RS-232 ports are provided by installing RSIS piggy-back PCBs onto
the RSIU PCB. The optional built-in modem is provided by installing an RMDS piggy-back PCB
onto the RSIU (see
The RSIS PCB can support any one of the hardware devices listed above via its RS-232 modular
jack. The RMDS PCB can function two ways: the RMDS can operate like an RSIS allowing it to
support any one of the hardware devices listed above locally from its RS-232 modular jack; or, the
RMDS can operate as a 1200 bps (bits-per-second) or 2400 bps system remote maintenance
modem.
The RMDS PCB function (modem or RS-232 port) is set in a system program option. The RMDS
can be set for one function only; it cannot support both functions simultaneously. When configured
as a modem, the RMDS PCB supports only the DK424 and DK424i remote maintenance, ASCII
terminal, or DKi Backup, and DKi Admin functions, and does not simultaneously support SMDI,
SMIS, SMDR, etc. (See
The total bits-per-second (bps) data rate of the four RSIU, RSIS, RMDS (RS-232/modem) ports
combined cannot exceed 9600 bps. The RSIU, RSIS RS-232 ports can be individually set in
system programming to operate at 1200 bps, 4 ports max.; 2400 bps, 3 ports max.; 4800 bps, 2
ports max.; or 9600 bps, 1 port max.; or, any other combination that does not exceed 9600 bps. The
RMDS modem function can be set to operate at 1200 bps or 2400 bps; however, if the RMDS port
is used as a RS-232 port instead of a modem, it can also be set for 4800 bps or 9600 bps.
The TTY and modem function cannot operate on separate RSIU, RSIS, RMDS ports
simultaneously. If both functions are programmed at the same time on separate ports, the function
of the lowest numbered RSIU, RSIS, RMDS port (TTY or modem) will be active.The
communication parameters for all RSIU, RSIS, RMDS port function types except the SMDR are:
♦
Data word bits = 7
♦
Parity = even
♦
Stop bits = 1
The communication parameters for an RSIU, RSIS SMDR port is:
♦
Data word bits = 8
♦
Parity = none
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...