Peripheral Installation
Relay Control Options and Door Lock Control
12-18
Strata DK I&M 6/00
2. If using a PIOU or PEPU, set the P11 jumper plug on the PIOU or PEPU to the MAKE or
BREAK position, as required:
♦
MAKE – Shorts the normally open contacts (pins 9 and 34) when any CO line is on hold.
♦
BREAK – Opens the normally closed contacts (pins 9 and 34) when any CO line is on
hold.
...or
If using a PIOUS, solder the W2 jumper on the PIOUS to the MAKE or BREAK position, as
required:
♦
MAKE – Shorts the normally open contacts (NHT and NHR) when any CO line is on
hold.
♦
BREAK – Opens the normally closed contacts (NHT and NHR) when any CO line is on
hold.
3. Connect the PIOU, PIOUS, or PEPU to the MDF as required for the MOH Relay function.
DK14 KSU and DK40i KSU Relay
The DK40i KSU Relay can be programmed for one of three options:
♦
BGM mute
♦
Night transfer
♦
MOH source control
These options are set in Program 77-1 (LED 05 and 06). Only one option is allowed per
installation. However, in the DK40i, these options can be supplemented with PIOU/PIOUS relay
options. Electrical specifications for the DK40i base relay contacts are:
Voltage
:
24VDC maximum
Current
:
♦
1 amp maximum
♦
Normally open – closed when activated
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...