Peripheral Installation
SMDR Printer/Call Accounting Device Options
12-38
Strata DK I&M 6/00
♦
Caller hangs up.
♦
The call releases, and Printout C prints after the call disconnects at 12:22.
Notes
●
If the CO provides the Calling Party Control or Auto Release (AR) signal (see Program 15-0
and 15-3), the call disconnects when either party hangs up. A “*” will follow the CO line
number in Release 1 and 2 and precede the CO line number in Release 3 on the printout if the
call is disconnected by the CPC or AR signal.
●
If the CPC or AR signal is not sent, the CO lines will remain seized until the DISA disconnect
timer releases the call (see Program 12).
Printout C
Auto Release signal: (Release 1 and 2)
003 MSS 12:20 00:00;02 00:06 (outgoing)
003* DISA 12:22 00:02;01 (outgoing)
001 DISA 12:22 00:02;01 (incoming)
Auto Release signal (Release 3 and above)
003 MSS 12:20 00:00;03 00:05 DISA (outgoing)
*003 DISA 12:22 00:02;01 (outgoing)
001 DISA 12:22 00:02;01 (incoming)
Disconnect Timer (Release 1 and 2)
001 DISA 12:24 00:04;57 (incoming)
003 DISA 12:24 00:04;57 (outgoing)
Disconnect Timer (Release 3 and above)
001 DISA 12:24 00:04;57 (incoming)
003 DISA 12:24 00:04;57 (outgoing)
Note
The “MSS” entry prints out only if the call was connected after the SMDR threshold, 1.0
or 10 seconds. The threshold is set in Program 60-2.
SMDR Programming
Program 03
♦
The SMDR output is provided by the PIOU or PIOUS with the lowest code assigned (41, 42,
or 43).
♦
If using RSIU or RSIS PCB (DK424) in slot 11 for SMDR, set Program 03 code 49 for slot 11.
Notes
●
WSIU (DK14) and TSIU (DK40i) do not require a Program 03 slot assignment.
●
RSIU/RSIS (DK424) Program 76-1 code x2 overrides PIOU/PIOUS SMDR assignments and
code 49 for RSIU/RSIS.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...