ISDN Interfaces
RPTU Installation
Strata DK I&M 6/00
16-11
ISDN
Inte
rface
s
Cabling
To meet Part 15 of FCC Rules, ISDN PRI equipment must be connected using CAT5, Shielded
Twisted-Pair (STP) cabling between the CSU and the RPTU. CAT5 STP protects against cross
talk, Radio Frequency Interference (RFI), and/or Electro Magnetic Interference (EMI). STP
protects ISDN signal data while being transmitted through the cable and keeps the cable itself from
emitting EMI and RFI.
Important!
To avoid ground loops, connect only the RPTU end of the shielded cable to ground.
The DK grounds the CAT5 cable shield between the DK and CSU at the RPTU RJ45
jack. You do not have to connect the CSU ground drain. The CSU ground should not
be connected to the cable shield.
Shield continuity must be maintained from the RPTU to the CSU, particularly if using extension
connecting cables. Keep the cable as short as possible between the CSU and the PRI Demarcation
jack, because there is no shield between the CSU and the Demarcation jack.
Toshiba provides a cable kit (Part No. RPRI-CBL-KIT), that contains all that you need to connect
the network ISDN jack to the network side of most CSUs and the equipment side of the CSU to the
RPTU PCB. Depending on the manufacturer, the CSU may use DB15 or modular jacks. If the CSU
is equipped with the modular jacks, the DB15/modular adapters are not used. If this is the case,
make sure the CSU modular jacks are not shielded jacks. Refer to
for more
information.
A detailed pinout diagram for the RJ45 jacks (USOC RJ48C or RJ48X) and the modular cords/
adaptors is shown in
Cable Length
The distance between the RPTU and CSU or RPTU and other Customer Premise Equipment (CPE)
may vary (0~655 ft.). The RPTU must be equalized and its impedance must match the impedance
of the connecting cable. Set SW1 on the RPTU for the proper cable length as shown in
for switch locations.
Table 16-9
SW1 Settings
Notes
♦
The modular pins are numbered left to right when looking into the jack cavity with the locking
clip down.
♦
Shield continuity must be maintained between the RPTU and the CSU, particularly on
extension cords. Since there is no shield continuity across the CSU and network jack, the cable
should be kept as short as possible.
SW1
Short
(0 - 150 ft.)
Medium
(150 - 450 ft.)
Long
(450 - 655 ft.)
1
On
Off
Off
2
Off
On
Off
3
Off
Off
On
4
Off
On
Off
5
Off
Off
On
6
Off
On
Off
7
Off
Off
On
8
Not Used
Not Used
Not Used
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...