DK40i Installation
MDF Wiring Diagrams
3-42
Strata DK I&M 6/00
MDF Wiring Diagrams
Wiring diagrams for the DK40i (listed below) are shown in
♦
MDF Wiring to KSU & Amphenol Station and Relay Connectors (KSTU2)
♦
MDF Wiring to CO Lines and Digital Telephones (KCDU)
♦
MDF Wiring to CO Lines (TCOU and TDDU)
See
Chapter 10 – Universal Slot PCB Wiring
Diagrams for more information.
Note
See
Figure 3-25 MDF Wiring to KSU & Amphenol Station and Relay Connectors (KSTU2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
W-BL
BL-W
W-O
O-W
W-GN
GN-W
W-BR
BR-W
W-S
S-W
R-BL
BL-R
R-O
O-R
R-GN
GN-R
R-BR
BR-R
R-S
S-R
BK-BL
BL-BK
BK-O
O-BK
BK-GN
GN-BK
BK-BR
BR-BK
BK-S
S-BK
Y-BL
BL-Y
Y-O
O-Y
Y-GN
GN-Y
Y-BR
BR-Y
Y-S
S-Y
V-BL
BL-V
V-O
O-V
V-GN
GN-V
V-BR
BR-V
V-S
S-V
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25
Bridging
Clips
To Base Unit (P5)
W/Female Connector
25-Pair Cable with Male Amp Connector
66M150 Split Block
Circuit 2 to DKT24
or PDIU-DS
Circuit 3 to DKT3
or PDIU-DS or
DDCB
Circuit 4 TO DKT4
or PDIU-DS or
DDCB
Circuit 6 to DKT6
or PDIU-DS
Circuit 7 to DKT7
or PDIU-DS
Circuit 5 or DKT5
or PDIU-DS
(-) T1 (Voice/Data)
(GND) R1 (Voice/Data)
(-) PT1 (Add, Power)
(GND) PR1 ((Add, Power)
T2
R2
PT2
PR2
T3
R3
PT3
PR3
T4
R4
PT4
PR4
T5
R5
PT5
PR5
T6
R6
PT6
PR6
T7
R7
PT7
PR7
Not Used
Station Cabling
GN
6 5 4 3 2 1
Y
BL
R
BK
W
3 4
R1
PT1
T1
PR1
2
5
PR TR PT
RJ11
Digital Telephone (DKT 1)
(With or without ADM,
RPCI-DI)
Modular
Cord
GND
PR
(-)
T
GND
R
(-)
PT
STD TEL
Circuit 1
Not Used
STD TEL
Circuit 2
or BGM
STD TEL
Circuit 3
STD TEL
Circuit 4
Not Used
Not Used
KSTU2
R1
T1
R2
T2
R3
T3
R4
T4
Circuit 8 to DKT8
or PDIU-DS
T8
R8
PT8
PR8
Relay
Contacts
1679
Jacketed Twisted Pairs
24AWG (1 or 2 pair)
T/R wires are always required;
PT/PR are additional power wires
required only for long station runs.
PT/PR may be used with normal
station runs also).
Voltage levels:
T, PT = –26.3 ~ 27.8 VDC
R, PR = 0.0 VDC (GND)
(Reference to FG ground)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...