DK424 Configuration
Features Capacities
Strata DK I&M 6/00
4-9
DK424 Configur
at
ion
Notes
●
T1 Lines can be in increments of 8, 16 and/or 24.
●
PRI channels can be in increments of 23B+1D or 47B+1D. Each B channel represents a PRI
CO line.
show system maximum capacity examples with ISDN BRI (S/T and/or U)
circuits.
Table 4-10
CO Loop Start Analog Lines with Caller ID Maximum Capacities
1 Cabinet
RCTUA
2 Cabinets
RCTUBA/BB
3 Cabinets
RCTUC/D
4 Cabinets
RCTUC/D
5 Cabinets
RCTUC/D
6 Cabinets
RCTUC/D
7 Cabinets
RCTUE/F
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
8
24
24
40
40
56
56
72
72
88
88
104
136
152
16
56
32
72
48
88
64
104
80
120
128
168
8
72
24
88
40
104
56
120
72
136
120
184
16
104
32
120
48
136
64
152
3112
200
24
136
40
152
56
168
104
216
32
168
48
184
96
232
40
200
88
248
80
264
Table 4-11
CO Ground Start with Caller ID, DID and/or Tie Analog Lines Maximum Combined Capacities
1 Cabinet
RCTUA
2 Cabinets
RCTUBA/BB
3 Cabinets
RCTUC/D
4 Cabinets
RCTUC/D
5 Cabinets
RCTUC/D
6 Cabinets
RCTUC/D
7 Cabinets
RCTUE/F
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
8
16
20
24
32
40
44
48
56
64
68
72
104
112
16
40
28
48
40
64
52
72
64
88
100
120
8
64
24
64
36
72
48
88
60
96
96
136
16
88
32
88
44
96
56
112
92
144
12
96
28
96
40
112
52
120
88
160
24
112
36
120
48
136
84
168
20
120
32
136
44
144
80
184
16
136
28
144
40
160
76
192
24
160
36
168
72
208
32
184
68
216
28
192
64
232
60
240
56
256
Table 4-12
Digital, Tie, DID, Ground/Loop Start Digital T1 and ISDN PRI Lines Maximum Combined
Capacities
2 Cabinets
RCTUBA/BB
3 Cabinets
RCTUC/D
4 Cabinets
RCTUC/D
5 Cabinets
RCTUC/D
6 Cabinets
RCTUC/D
7 Cabinets
RCTUE/F
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
Lines
Stations
48
56
72
88
112
112
120
152
144
144
192
1
1. The maximum number of PRI lines for 2 cabinets is 47, 3~6 cabinets is 141 and 7 cabinets is 188.
240
40
64
64
96
96
120
112
160
120
168
184
248
24
72
48
104
88
128
96
168
112
176
168
264
16
80
40
112
72
136
88
176
96
192
160
272
24
120
64
144
72
184
88
200
144
288
16
128
48
152
64
192
72
216
136
296
40
160
48
200
64
224
120
312
24
168
40
208
48
240
112
320
16
176
24
216
—
—
96
336
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...