DK424 Configuration
Features Capacities
4-10
Strata DK I&M 6/00
Table 4-13
RCTUA Maximum Capacity Examples with ISDN BRI (S/T and/or U-type) Circuits
Table 4-14
RCTUBA/BB Maximum Capacity Examples with ISDN BRI (S/T and/or U-type) Circuits
BRI Station
Circuits
BRI Station
B channels
Other Station
Circuits
3
BRI Line
Circuits
4
BRI Line
B channels
4
Other Line
Circuits
5
8
2
16
2
16
0
0
0
6
12
16
2
4
0
5
10
16
3
6
0
4
8
16
4
2
8
2
0
4
8
16
2
4
4
3
6
16
1
2
8
2
4
24
2
4
8
1
2
28
1
2
12
BRI Station
Circuits
1
BRI Station
B channels
1
Other Station
Circuits
3
BRI Line
Circuits
4
BRI Line
B channels
4
Other Line
Circuits
5
16
2
32
2
32
8
2
16
2
0
12
24
40
8
16
8
10
20
40
8
16
12
8
16
48
8
16
16
8
16
48
6
12
20
8
16
56
4
8
24
8
16
56
2
4
28
6
12
56
6
12
24
6
12
56
4
8
28
6
12
64
2
4
32
4
8
64
4
8
32
4
8
64
2
4
32
2
4
72
2
4
40
1. Each BRI circuit (S/T and/or U-type) provides two B channels plus one D channel and reduces the system capacity by two
station ports and two CO lines. Each (S/T) BRI station circuit allows up to eight TE-1 and TA devices to share the BRI B
channels (two simultaneous calls maximum per BRI circuit). Each BRI-U circuit supports one TE-1 or TA device.
2. Maximum BRI capacity.
3. Conventional stations include Toshiba digital and electronic telephones, or attendant consoles, standard telephones and
devices.
4. BRI S/T circuits are available with RBSU/RBSS PCBs and BRI-U circuits are available with RBUU/RBUS PCBs. ISDN
BRI PCBs will be available with a future release of DK424 software. Each BRI line circuit (S/T or U) provides two BRI CO
lines (channels) for incoming/outgoing calls.
5. Conventional lines include analog and digital (T1 or PRI) loop start, ground start, DID, and Tie lines.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...