DK424 Installation
Site Requirements
5-2
Strata DK I&M 6/00
Site Requirements
Input Power
The DK424 requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 17.5 amps. The
system requires one or two AC outlets that must be dedicated to system use, fused, and grounded.
DK424 expansion cabinets installed at remote locations require their own 10VAC, 50/
60 Hz power sources. Each Remote Expansion Cabinet requires 2.5 amps. The system or remote
cabinet installation requires one or two AC outlets that must be dedicated to system use, fused, and
grounded.
See
“Power Supply Installation” on Page 5-8
for complete AC power cabling, ground wiring and
battery installation instructions for local and remote cabinets.
CAUTION!
To avoid accidental power turn-off, it is recommended that an On/Off wall
switch not be used on AC circuits dedicated for the use of DK424.
A reserve power source (two or four customer-supplied 12-volt batteries) may be connected to the
DK424 to serve as a backup in case of power failure.
Separate reserve power may be required for remote expansion cabinets.
Clearance and Location
The Base and optional Expansion Cabinets may be either floor or wall mounted.
shows
the minimum clearance requirements. See
Distribution for Six Cabinets” on Page 5-36
for details.
Notes
●
Floor mounting requires the following additional hardware:
●
RFIF – floor mounting stands and brackets.
●
RCCB – electrical conduit box, if three or more cabinets are installed.
●
Wall mounting may require a plywood (3/4 inch thick) backboard.
When selecting a location for the cabinets, the location
must be:
♦
Dry and clean
♦
Well-ventilated
♦
Well-illuminated
♦
Easily accessible
The location
must not be
:
♦
Subject to extreme heat or cold
♦
Subject to corrosive fumes, dust, or other airborne contaminants
♦
Subject to excessive vibration
♦
Next to television, radio, office automation, or high frequency equipment
Optional customer-supplied reserve batteries require a well-ventilated location close (within nine
feet) to the DK424 cabinets.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...