DK424 Installation
Site Requirements
5-6
Strata DK I&M 6/00
Network Requirements
The system network requirements are provided in
Note
Digital trunks (RDTU, RPTU) may be installed in a Remote Expansion Cabinet; however,
the system can only derive Network Clock Synchronization from digital trunks installed in
a Base Cabinet.
Table 5-3
DK424 Network Requirements
PCB/Interface
Facility Interface Code
Network Jack
Ringer
Equivalence
Universal Service
Order Code
PESU/RSTU2/RDSU
1
(Off-premises Station)
1. Only PESU circuits 1 and 2, and RDSU circuits 1~4 provide Off-premises Station (OPS) capability. PESU must use OL13A or
equivalent line conditioning for OPS connection. RDSU must use OL13A or OL13B if providing –24 volt loop voltage. If
equipped with the –48 volt loop option PCB (R48S), OL13A, OL13B, or OL13C may be used for OPS connection.
OL13A (PESU)
RJ21X
N/A
9.0F
OL13B (RSTU2, –24V)
OL13C (RSTU2, RDSU
with R48S-48V)
RCOU/RCOS
(loop start line)
02LS2
RJ14C/RJ21X
0.3B
N/A
RDDU
02RV2-T
RJ14C/RJ21X
0.0B
AS.2
REMU type 1 or type 2
TL11M, 2-wire
TL31M, 4-wire
TL12M, type 2, 2-wire
TL32M, type 2, 4-wire
RJ2EX
RJ2GX
RJ2FX
RJ2HX
Not Available
(N/A)
9.0F
RGLU2 (ground or loop start
line)
02GS2 (ground)
02LS2 (loop)
RJ14C/RJ1CX
0.3B
N/A
RDTU (DS-1/T1)
2
2. When ordering DS-1/T1 circuits, six items must be specified:
The number of channels per T1 circuit, fractional increments are normally 8, 12, or 16 channels, full service is 24 channels.
Unused channels must be bit-stuffed.
Type of CO line assigned to each channel: Loop Start, Ground Start, Tie (Wink or Immediate Start), DID (Wink or Immediate).
Frame Format Type: Super Frame (SF) or Extended Super Frame (ESF). The T1 provider normally specifies the Frame Format
to be used, either is adequate for DK424 CO digital voice lines. ESF provides a higher level of performance monitoring, but
requires trained personnel and the ESF CSU normally costs more than an SF only CSU.
Line Code Type: Alternate Mark Inversion (AMI) or Bipolar 8 Zero Substitution (B8ZS). The T1 provider normally specified
the Line Code to be used, either is adequate for DK424 T1 CO digital voice lines.
The customer may have to provide the Channel Service Unit (CSU) to interface the DK424 T1 circuit to the Telco T1 circuit.
(CSUs are a Telco requirement.)
RDTU Network Channel Interface Codes: 04DU9-BN, 04DU9-DNZZ, 04DU9-1SN, 04DU9-1KN, 04DU9-1ZN.
(See last bullet note on
Note 2 below.)
RJ48C/RJ48X/
RJ48M
N/A
6.0P
RCIU2/RCIS (Caller ID)
N/A
RJ21X/RJ14C
0.3B
N/A
RPTU (PRI)
3
3. For information on how to order ISDN PRI/BRI circuits, you should refer to the Toshiba ISDN Training CBT. ISDN circuits
may require a customer-provided CSU for PRI and/or Terminal Adapter or Network Terminal units for BRI. In U.S. CSU/TAs
must be UL-listed in the U.S. In Canada, they must be CSA certified.
04DU9-1SN
RJ48C/RJ48M
N/A
6.0P
RBSU/RBSS (S/T, BRI)
3
02IS5
RJ48C/RJ48X
N/A
RBUU/RBUS (U, BRI)
3
02IS5
RJ48C/RJ48X
N/A
RCMU/RCMS (CAMA)
02RV2-O
RJ11C/RJ21-X
N/A
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...