DK424 Installation
Cabinet Installation Considerations
Strata DK I&M 6/00
5-7
DK424 Installa
tion
Cabinet Installation Considerations
The Base (DKSUB424) and Expansion Cabinets (DKSUE424) can be wall or floor mounted. To
make it easier to add cabinets (after the initial installation) when a customer needs to expand,
install the Base Cabinet on top for wall-mount installations and on the bottom for floor-mount
installations.
The dimensions of the Base and Expansion Cabinets are:
Height:
Base Cabinet: 11 3/4 inches
Height:
Expansion Cabinet/Remote Expansion Cabinet: 10 inches
Width:
23 5/8 inches
Depth:
9 3/4 inches
Weight:
approx. 30.5 lbs. (14 kg.)
Note
The weight approximates a cabinet completely filled with PCBs. Weight may vary
slightly, depending on PCBs.
Recommended Installation Sequence
Note
Each cabinet requires four wood screws (#12X 1.25 inch size) for wall mount installation.
Wood screws are not provided with the system.
Step
Reference Information
1.
Install power supplies in cabinets.
“Power Supply Installation” on Page 5-8
2.
Mount cabinets on floor or wall.
“Cabinet Floor Mounting” on Page 5-21
.
3.
Install ground wiring.
“AC Power and Third Wire Ground Test” on Page 5-29
.
4.
Install AC power cabling to cabinets.
“AC Power Cabling Installation” on Page 5-30
5.
Install reserve power cabling.
“Reserve Power Installation” on Page 5-32
6.
Install PCBs and PCB cabling.
.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...