DK424 Installation
RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units
Strata DK I&M 6/00
5-47
DK424 Installa
tion
Figure 5-29 RCTU Slot Placement
Maximum Line Capacities
Configurations for a fully-expanded system can range from 40 lines/ 336 stations to a squared
system of 200 outside lines/192 stations.
Table 5-5
Maximum Line Capacities by Processor Type
Common Control Unit
Number of Cabinets
Maximum
Lines
Stations
RCTUA
one Cabinet (Base Cabinet)
16
32
RCTUBA/BB
up to two Cabinets (Base Cabinet plus
one six-slot Expansion Cabinet)
48
80
RCTUC/D
up to six Cabinets (Base Cabinet plus up
to five more six-slot Expansion
Cabinets)
144
240
RCTUE/F
up to seven Cabinets (Base Cabinet
plus up to six more eight slot Expansion
Cabinets)
200
336
RCTUBB,
RCTUA,
or RCTUD
RCTUD only
To RSIU if installed
RCTUBA
or
RCTUC
Slot R11
Slot RCTU (Base Cabinet)
P3
P2
P11
P2
Heartbeat LED
4310
RCTUBB,
RCTUA,
or RCTUD
RCTUD only
To RSIU if installed
RCTUBA
or
RCTUC
Slot R11
Slot RCTU (Base Cabinet)
P3
P2
P11
P2
Heartbeat LED
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...