DK424 Installation
Remote Cabinet Installation Instructions
Strata DK I&M 6/00
5-61
DK424 Installa
tion
Remote Cabinet Installation Instructions
All instructions apply to both the Base Cabinet and the Remote Expansion Cabinet except where
specifically noted.
1. Install cabinets according to the instructions given at the beginning of this chapter. Pay
particular attention to wiring and grounding instructions given for Remote Expansion
Cabinets.
2. If installing a standalone Remote Expansion Cabinet, or the first in a stack, install the power
supply Base Jumper Plug in accordance with
.
3. Cabinets in which RRCU1A cards are installed
must be modified to protect the routing of the
cables through the cabinet.
♦
Remove the existing data cable door as
shown in
.
♦
Replace the original data cable door with the
data cable door provided with the RRCU1A
card. It has a protected opening through
which the remote data cables can pass.
♦
Attach the clamps bracket to the inner wall
of the cabinet (See
).
4. Install the RRCU1A Card
♦
Select correct jumper options (see
). On the Master side, both option plugs
connect the center pin to the upper pin (M).
On the Slave side, both option plugs connect
the center pin to the lower pin (S).
♦
Remove the protective rubber cap from the
fiber connector on the ROMS1A
daughterboard. See
5. Install an RCTC1A top cover on the topmost
cabinet.
4358
Figure 5-40 Remote Cabinet Hooks
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...