DK424i Configuration
Worksheet 6: DK424i Cabinet Slot Configuration
6-28
Strata DK I&M 6/00
Processor PCBs
♦
B1CU (Slot B102), provides slots S101 through S108 for Line, Station and Option PCBs.
Allows up to 2 RDTU and/or RPTU PCBs to be installed.
♦
B2CAU (Slot B101)/ B2CBU (slot B102), provides slots S101 through S206 for Line, Station
and Option PCBs. Allows up to 6 RDTU and/or RPTU PCBs to be installed.
♦
B3CAU (Slot B101)/ B3CBU (slot B102), provides slots S101 through S310 for Line, Station
and Option PCBs. Allows up to 6 RDTU and/or RPTU PCBs to be installed.
♦
B5CAU (Slot B101)/ B5CBU (slot B102), provides slots S101 through S510 for Line, Station
and Option PCBs. Allows up to eight RDTU and/or RPTU PCBs to be installed.
♦
Configure BRCS DTMF receivers and RKYS key on the processors as needed.
1. Programming Telephone Interface
♦
If RSIU is not needed, install a PDKU or PEKU in Slot S101
to accommodate the
programming telephone.
♦
If RSIU is needed, see Options PCBs in the next item below.
2.
Option PCBs for Paging/Remote Maintenance/ACD/SMIS/SMDR/RS-232 Interface
♦
See
Worksheet 5: Feature Option PCB
to determine the Option PCB requirements.
♦
RSIU with/without RSIS or RMDS. This PCB must be installed, if needed, in Slot S101 only.
If RSIU is installed in S101 then a PDKU or PEKU must be installed in S102 to accommodate
the programming telephone.
♦
PIOUS, PIOU, RSSU, PEPU each requires one slot. These PCBs should be installed after all
other PCBs are installed. They cannot occupy any slot that is left vacant to provide RDTU,
RPTU, or RWIU capacity as shown in
. However, the PIOUS, PIOU, RSSU,
PEPU PCBs can occupy any other slot that is vacant.
3.
Remote Cabinet PCBs
♦
RRCU PCBs installed in the main location must be placed in Base Cabinet slots S102~S108 in
any order. Before installing other PCBs make sure there is a Base Cabinet slot available for
each RRCU PCB needed. An RRCU may occupy a vacant slot adjacent to RDTU, RPTU, and/
or RWIU. An RRCU PCB in a remote location can support one or two remote cabinets and can
be installed in any slot of either cabinet.
The number of RRCU PCBs required in the Base and Remote Cabinet locations is shown in
Table 6-17
RRCU PCB/ Remote Cabinet Configuration
RRCU PCBs
Needed in
Base Cabinet
Remote Cabinet Configuration
RRCU PCBs Needed at
Remote Location (s)
1
1 or 2 Remote Cabinets in one location
1
2
2 to 4 Remote Cabinets in two locations or 3 to 4
Remote cabinets in one location.
2
3
3 cabinets if cabinets are in separate remote locations.
3
4
4 cabinets if cabinets are in separate remote locations.
4
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...