DK424i Configuration
Worksheet 6: DK424i Cabinet Slot Configuration
Strata DK I&M 6/00
6-31
DK424i Configuration
7.
Digital and Standard Telephone Station PCBs
♦
See
Worksheet 3: Standard Telephone
to determine station PCB requirements.
♦
PDKU, RSTU, RDSU/RSTS, PEKU, and PESU: Each PCB or PCB combination requires one
slot. These PCBs can not occupy a slot that is left vacant to provide capacity for RDTU,
RPTU, or RWIU as shown in
,
. Each PCB provides up to eight
circuits for the type of stations it supports.
Table 6-21
Strata AirLink RWIU PCB Cabinet Slot Configuration
Handsets
Needed
Slots
Needed
RWIU PCBs Needed
1
1. RWIU PCBs do not have to be installed in the order shown in this table. Example: If only one RWIU is
needed, it can be installed in any RWIU slot shown in the table so long as the slot is supported by the
installed processor.
RWIU Cabinet Slot Placement
1
Base Cabinet with Any Processor
1~8
1
1
S103-RWIU1
9~16
2
S104-vacant
2
2. The slot occupied by RWIU supports eight handsets, for each additional eight handsets an additional
slot(s) adjacent to RWIU must be vacant.
17~24
3
2
S105-RWIU2
24~32
4
S106-vacant
2
33~40
5
3
S107-RWIU3
41~48
6
S108-vacant
2
Second cabinet with B2CAU/CBU processor
1~8
1
1
S201-RWIU1
9~16
2
S202-vacant
2
17~24
3
2
S203-RWIU2
24~32
4
S204-vacant
2
33~40
5
3
S205-RWIU3
41~48
6
S206-vacant
2
Second and third
cabinet with B3CAU/CBU; or second through fifth
cabinet with B5CAU/CBU
1~8
1
1
S_07-RWIU1
9~16
2
S_08-vacant
2
17~24
3
S_09-vacant
2
24~32
4
S_10-vacant
2
33~40
5
2
S_01-RWIU2
41~48
6
S_02-vacant
2
49~56
7
3
S_03-RWIU3
57~64
8
S_04-vacant
2
65~72
9
4
S_05-RWIU4
73~80
10
S_06-vacant
2
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...