Universal Slot PCBs
PCB Chapter Layout
Strata DK I&M 6/00
9-5
Universal Slot PCBs
4. After installing the BVPU, gently pull it outward. If the connectors are properly mated, a slight
resistance is felt.
Figure 9-1
BVPU Monitor Jack
BVPU Programming
Note
For programming purposes, the Strata DK regards the BVPU card as an REMU and
identifies it as such
.
Programming instructions for the gateway component are included in
the Voice Over IP Installation Guide.
♦
Program 03: Specify Code 13 for slots that support REMUs (BVPUs) and make sure RRCS is
enabled for DTMF operation.
♦
Program 04: Specifies [PDNs]. These are also the numbers that must be received by incoming
Tie lines to route calls to the proper telephones (see Program 17, LED 05).
♦
Program 10-1: Enables/disables two-line conference.
♦
Program 15: Assigns tandem connections and dial pulse option to Tie lines.
♦
Program 17: Assigns immediate or wink start to BVPU Tie lines.
Important!
Also used to turn on Tie line dial tone return.
Note
When a BVPU is installed in a system, it automatically assumes the next four consecutive
CO line and station port numbers.
♦
Program 30: Disables RRCS for dial pulse operation.
♦
Program 71 (1~5) and Program 72: Tie/DID DNIS assignments.
♦
Program *71~*73: DH/Tie/DID to [DN] ringing assignments.
♦
Program 93: Assigns a name to a Tie line
RD
TD
DSR
DTR
DCD
SG
1
2
3
4
5
6
Call-monitor jack (RJ12)
pin numbering
Dealer-supplied
6-wire telephone
modular cord
(cross-pinned)
Monitor jack
PC with maintenance
console software
PC DB9 or
DB25 Com port
Toshiba PPTC9 or
PPTC25F
BVPU
5243
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...