Universal Slot PCBs
PCB Chapter Layout
9-22
Strata DK I&M 6/00
Note
PIOU2 or PIOUS2 connectors P1, P2, and P3 are positioned to allow installation of the
IMDU2 only in the proper position.
7. Refer to the
Strata DK Programming Manual
and turn LED 14 on in Program 77-1 to enable
IMDU2 operation.
Note
The IMDU2 default station intercom or [DN] is #19.
8. Apply firm, even pressure to the IMDU2 to ensure proper mating of connectors.
9. Set the SW2 baud rate switch on the front panel to 300 or 1200, as appropriate, after the PCB
has been installed in the KSU/cabinet (in for 300 bps, out for 1200 bps).
Note
Chapter 12 – Peripheral Installation
for external option installation procedures.
PIOU2, PIOUS2 Installation
1. Make sure that P15 is in the Mu Law position for USA and Canada.
2. Ensure that the PIOU2 or PIOUS2 has been configured for the appropriate hardware options.
Chapter 12 – Peripheral Installation
3. Insert the PIOU2 or PIOUS2 (component side facing right) into the last slot (“S16”) of the
Base KSU/cabinet if the system only has a Base KSU/cabinet and no Expansion KSUs/
cabinets. If there are Expansion KSUs/cabinets, install the PIOU2 or PIOUS2 in the highest
slot number in any KSU/cabinet. Apply firm, even pressure to ensure proper mating of
connectors.
Note
In DK40i, PIOU2 or PIOUS2 can be installed in any available Expansion KSU.
4. After installing the PIOU2 or PIOUS2, gently pull the PCB outward. If the connectors are
properly mated, a slight resistance is felt.
PIOU2, PIOUS2 Programming
Program 03: Specify Code 41, 42, or 43 for the slot that will support a PIOU2 or PIOUS2. (See
“Multiple Serial Port Installation” on Page 13-2
Note
Program 76 assignments for RSIU, RSIS, RMDS will override Program 03 assignments
(41, 42, and 43) for SMDI, SMDR, TTY, and maintenance modem.
Program 10-2: Activates External Page with All Call Page (with access code #39 only, not with
$OO
&DOO3DJH
button).
Program 60: Assigns SMDR options.
Program 77-1: Assigns relay control and IMDU2 options.
Program 78: Sets Night Ringing over External Page
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...