Universal Slot PCBs
RDTU – T1 Interface Unit
Strata DK I&M 6/00
9-53
Universal Slot PCBs
➤
To install an RSIU PCB into an existing system with DID and/or Tie lines
Note
The steps in
apply to installing an RSIU into an existing
system. Hence, most PCBs must be moved to the next highest slot using the following
steps.
1. Identify (mark) all PCB wiring connectors so they can be removed and then reinstalled onto
the same station PCB later.
2. Turn system power Off.
3. Disconnect the connectors from all PCBs except PIOU2, PIOUS2, RSSU, PEPU, RCIU, and
RCIS.
4. Remove all PCBs except PIOU2, PIOUS2, RSSU, PEPU, RCIU, and RCIS.
5. Each PCB that was removed must be installed into the next highest empty PCB slot number.
Skip over all other types of PCBs that were not removed.
Note
This step may have to be modified for the RDTU PCB, depending on the configuration to
meet the requirements of RDTU slot assignments per tables in
6. Connect all PCB connectors that were removed back into the same PCBs from which they
were removed.
7. Turn the system power on and note that the programming telephone is on port 13 and all other
ports are shifted up by eight ports. Program slot 11 with Code 49 and all other slots with the
appropriate codes using Program 91-1 and/or 03.
Next, cycle system power Off (5 seconds) and on or, run Program 91-2 to transfer Program 03
data from temporary to working memory. At this time the programming telephone changes
from port 13 to port 005 and all other ports shift down by eight ports.
RSIU, RSIS, RMDS Programming
Program 03: Programs slot 11 with code 49 to identify that the RSIU PCB is installed in slot 11.
Program 76-1X-Y: Assigns each installed RSIU port to a function. Where X identifies the RSIU
port no. 1~4 (see
for RSIU port number configuration) and Y identifies the RSIU port
function:
♦
Y=1, RS-232 TTY (Program 77-1, LED 14 Off)
♦
Y=1, RMDS modem (Program 77-1, LED14 On)
♦
Y=2, SMDR
♦
Y=3, MIS or SMIS
♦
Y=4, SMDI
♦
Y=5, Open Architecture
♦
Y=0, No function - this should be used for any of the four RSIU, RSIS, RMDS ports that are
not used.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...