Station Apparatus
Digital Add-on Module Installation
Strata DK I&M 6/00
11-39
Station Apparatus
Digital Add-on Module Installation
Install one or two DADM 2020s to a 2000-series digital telephone (only).
♦
DK14
supports up to 8 DADMs
♦
DK40i
supports up to 12 DADMs
The number of DADMs supported by the DK424 depends on the common control PCB:
♦
RCTUA
supports 12 DADMs
♦
RCTUB
and
B1CAU
supports 40 DADMs
♦
RCTUC/D B2CAU/BU, B3CAU/BU
supports 120 DADMs
♦
RCTUE/F
and
B5CAU/BU
support 200
DADMs
The DADM provides DSS buttons, speed dial
buttons and CO line buttons.
Notes
♦
See the appropriate system Installation
Chapter for loop length and secondary
protection requirements.
♦
DADMs cannot be installed on telephones that
have RPCI-DI on OCA/DVSU installed.
➤
To install DADMs
See
and follow these steps:
1. Loosen the four captive screws on the 2000-
series digital telephone base and remove the
base.
2. Remove the base handset hanger.
3. Loosen two captive screws on DADM and remove bases.
4. Put the DADM supplied cable through the telephone and DADM bases.
5. Connect DADM cable connectors to P1 of DADM and P1 of DKT2000 telephone.
6. Install base of DADM and telephone– tuck DADM cable into DADM and telephone base, as
necessary, for proper length.
7. Secure DADM to telephone base with DADM connecting plate (using four screws).
8. If required to achieve maximum distance, install 2-pair house cable (or external power) and 2-
pair modular cord, supplied with DADM. (See
Chapter 10 – Universal Slot PCB Wiring
.)
9. If a second DADM should be installed, connect P1 of the second DADM to P2 of the first
DADM with the DADM connecting cable.
1870
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...