Peripheral Installation
Relay Control Options and Door Lock Control
12-12
Strata DK I&M 6/00
Figure 12-8
PIOUS Relay Control Functional Wiring Diagram
Normal
Close
Normal Open
ALM.T
ALM.R
NH.R
NH.T
DE.R
DE.T
SP.R
SP.T
Break
W1 Make
K1
W2
K2
W3
PIOUS
ALM
NH
DE
600
TBI
Night Bell
Break
Make
Mute
Control
KSU Backplane
MDF
1508
Notes
• All wiring connections must be 24 AWG twisted pairs.
• Dotted lines and solid lines differentiate optional connections where applicable;
do not connect both options simultaneously.
Relay Options:
• K1 (DE): Door Lock or amp Mute Control; Program 77-1, LED 07
• K2 (NH): Night Relay or Music-on-Hold Control; Program 77-1, LED 05
• K1 & K2: 24VDC, 1 amp Maximum
Page
Amplifier
Door
Lock
Control
MOH
Source
Unit
Facility
Alarm
Unit
Alarm
Sensor
Page
and
BGM
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...