Peripheral Installation
Relay Control Options and Door Lock Control
12-16
Strata DK I&M 6/00
Figure 12-10 Multiple Door Lock Control Options (DDCB/HDCB)
Night Transfer/Night Relay Options with PIOU, PIOUS, or PEPU
Night Transfer/Night Relay option may be programmed for either the Night Relay or the MOH
relay function. (See
Note
Only the PIOU/PIOUS, or PEPU with the lowest Program 03 code (41, 42 or 43) will
provide the Night Transfer (NT) or MOH relay control function.
When configured for the NT function with Program 77-1, the relay activates if the system is in the
Night mode. The relay can be programmed to activate continuously when the
1LJKW7UDQVIHU
button (only) is set for the Night mode (for indirect answering machine control), or to pulsate at
one-second On/three-seconds Off (for a night bell) when incoming CO lines ring (Night Transfer
1~4 = tenant 1~4 CO lines) per Program *15 and 77-3.
When configured for the MOH function with Program 77-1, the relay activates any time a CO line
is on hold. In this configuration, the relay is normally used to control the MOH source.
DK14 KSU,
DK40i KSU,
PDKU,
RDSU,
PEKU,
or
PESU
(See Chapter 8—
Wiring Diagrams)
DDCB or HDCB
A
C
2
B
3
4
5
RJ11
3
4
2
5
Relay Contact
to Customer
Supplied
Device
MDFB
1
2
RJ11
3
4
MDFB
1
RJ11
3
4
MDFB
1
3
4
Door Phone
A
Door Phone B
or
Door Lock Control
2
2
Door Phone
C
3
4
HDCB WIRING CHART
PEKU or PESU to
HDCB KSU Jack
VT (34) / VR (9)
DT (35) / DR (10)
to
to
PIN 3 / 4
PIN 5 / 6
DDCB Wiring Chart
See Chapter 8—Wiring for PEKU, PESU, PDKU or RDSU pin-out information.
See DK14 and DK40i Installation chapters for appropriate pin-out information.
Relay
Control
Contact
PDKU or RDSU to
DDCB KSU Jack
DT (34) / DR (9)
to
PIN 3 / 4
PT (35) / PR (10)
to
PIN 5 / 6
Notes
1. Relay control contact will close when the door phone is in the ringing, talk, or monitor state.
2. See External Page/Door Lock Relay Options on Page 10-14 and DDCB and HDCB/DRLK
Assignments Guide on Page 10-19.
3. Relay contact specifications are -24VDC at 1.0 amp. max. Do not connect relay contacts to 120
AC commercial power.
4301
Door Lock
Control
Contact
2
1
3
DK14 (Ports 002, 003)
DK40i/DK424 (Ports 004,
012, 020)
DK424 (Port 028)
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...