Peripheral Installation
DK Alarm Sensor
Strata DK I&M 6/00
12-73
Pe
ri
p
h
er
a
l In
st
al
la
ti
on
Figure 12-38 DK PC Auto Dial Voice Call Test
DK Alarm Sensor
The PIOU or PIOUS PCB provides a circuit that can be set to detect a relay open or closed
condition from a facility alarm system. When the sensor is activated, all electronic and digital
telephones sound an alarm signal. The electronic/digital telephone alarm signal can be reset by any
electronic or digital telephone with an
$ODUP5HVHW
button (see Program 39).
Alarm Sensor Options
Note
See
Jumper plug P12 on the PIOU is used to set the alarm sensor to detect an open or closed condition
from the facility alarm system.
➤
To detect an open or closed condition by the jumper plug P12
1. To detect a closed condition, set P12 to the N.O. position.
2. To detect an open condition, set P12 to the N.C. position.
Jumper W3 on the PIOUS is used to set the alarm sensor to detect an open or closed condition
from the facility alarm system.
➤
To detect an open or closed condition by soldering the W3 jumper wire
1. To detect a closed condition, solder W3 to the normal open position.
2. To detect an open condition, solder W3 to the normal closed position.
Alarm Sensor Wiring
See
, and connect the facility alarm system relay contacts to the PIOU/PIOUS PCB.
Digital
(Port 001)
MDF
RS-232
Portable PC 2
DKT/RPCI-DI or
DKT/PDIU-DI
(201)
MDF
CO
LINE 1
Public
Telephone
Network
Standard
Telephone
Strata DK
Dialed Line
1540
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...