Peripheral Installation
Auto Attendant
12-80
Strata DK I&M 6/00
Flowchart 10-2 Built-in Auto Attendant Flowchart (continued
)
Non-built-in Auto Attendant
Alternatives to using the Strata DK built-in AA feature, are voice mail systems, such as Toshiba
Stratagy or VP, with an AA feature and non-voice mail AA as a stand-alone device.
Non-built-in Auto Attendant Programming
The Auto Attendant programs described in
“Built-in Auto Attendant Basic Call Sequences” on
do not apply to the Non-integrated AA feature sources, but Strata DK Programs 03, 04,
10-1, 13, 16, 31, 33, 36, 37, 39, and 81~89 should be considered for proper operation.
Non-built-in Auto Attendant Installation
Non-integrated AA sources, such as voice mail devices and stand-alone units, connect to standard
telephone circuits (ports). See
Chapter 10 – Universal Slot PCB Wiring
Answer
Talk
Auto Attendant Routes Call (Program 09):
*
Camp-On Timer
(Program 26)
(011-999S)
Caller Receives Music-On-Hold or Ring Back Tone
per Program 10-3, LED 15 When Auto Attendant
Routes Call
Camp-On Beep 10 IPS Fast LED
Flash LCD Camp-On Display
Ring DN for 16
Seconds
(see Note)
Dial Idle DN
Busy Station Becomes Idle
16 Seconds No Answer
Note
If the station has CF/NA set, the
station will ring for the CF/NA time
duration and then it will forward to
the forwarded destination. The
CF/NA destination station will ring
16 secs. and then route to
if not
answered. A call will not forward a
second time.
Program 24
Secondary Annoucement
Devices (A2, A2', A2'', A2''')
Assignments
KSTU2 / PSTU / RSTU /
RDSU / PESU
Dial
DISA Mode
Internal
Dial Tone
Dial: Wrong or Vacant
Number; or Dial a DND or
Ringing Station
A2 In
System?
No
Yes
Go to
Figure 10-44
ACD
Group
Overflow
To AA
Option
Programs
14-4, -5, and -6
Time-Out
Dial Busy or
Ringing DN
3
A
4
0
Check
Program 10-3
A1 + RRCS
Available?
15 Sec
A2 + RRCS or BRCS
Available?
No
(15 Second
Time Out)
Yes
1 Second Queue
Wait
A2'''
A2''
A2'
Ring A2
Ring Station per Program
(81, 84, 87) for 40/120/240
Sec. per Program 10-3
LEDs 16 and 17
No Answer
or Automatic
Release
Answer
Talk
Go to
Yes
No
Yes
Yes
Program 10-3
LED 18 (On)
No
(16 Second Wait for A2/RRCS, BRCS Available)
A2 Answers Within
16 Seconds
A2 Answers and Plays
Announcement
(60 Seconds Maximum; RRCS, BRCS Remains
4 Seconds After Announcement Disconnects)
2
Disconnect CO Line
Go to
4
Go to
Time-out 16 Seconds
(Faulty A2)
Figure 10-44
1545
1
5
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...