4. Connect the additional PCs the CCVY “MNTR1” or “MNTR2” port with a six-conductor line
cord. Use a PPTC-9 or PPTC-25F on the PC end of the cord.
Figure 13-20 Connecting Strata DK to Two or Three CCV PCs
Connecting the CCV to More than Three CCV PC
Use a Data Distribution Box when you are connecting more than three PCs using the CCV
software. You will also need the connectors listed on the previous page.
➤
To connect Strata DK to multiple CCV PCs
1. Install the CCVY connector into the Strata DK MIS port (RSIU, RSIS, RMDS, or PIOU
PCBs). See
2. Use a six-conductor twisted pair telephone cord to connect the DK MIS port to the “DK MIS”
port on the CCVY.
3. Plug a six-conductor modular plug into the “MASTER” port of the CCVY. Use a PPTC-9 or
PPTC-25F at the other end of the cord to connect to the SMIS or Main Call Center Viewer PC.
4. Make sure that the Data Distribution Box is strapped for DTE operation for every output port
(8). By using multiple data broadcast units, as many PCs as desired can be used, provided each
one has the Call Center Viewer application and key installed.
5. Plug in a six-conductor line cord to either the CCVY “MNTR1” or “MNTR2” port. connect
the other end to the Data Distribution box
...or
if the PCs are located more than 50 feet from the DK, use Line Driver Modem(s) to boost the
signal (see
). Use a a PPTC-9 or PPTC-25F to attach the recommended ME764-
MSP Line Driver modem. Connect the other end of the Line Driver modem directly into the
Data Distribution box.
2427
Master CCV PC
CCV PC#2
Wall Boards
CCV PC#3
CCVY
Connector
Strata DK
PPTC-9 or PPTC-25F connector
6-conductor, twisted pair phone cord
TECH SUPPORT CW:18 LCW: 15:10
MARKET SUPPORT CW:2 LCW: 1:56
CUSTOMER SUPPORT CW:5 LCW: 3:15
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...