Fault Finding
Fault Isolation Flowcharts
14-14
Strata DK I&M 6/00
Flowchart 14-5
DSS Console Faults
START
DSS
console
type?
5-0
END
DDSS
Go to
5-0
Is the correct
PCB slot code entered
in Program 03?
Enter correct PCB slot
code using Program 03;
then turn power OFF
(for 5 seconds) and
then ON.
5-3
Refer to Chapter 10 and verify wiring:
Is the
fault
cleared?
Yes
5-4
Go to
5-3
HDSS
No
On PEKU connected
to HDSS, set SW1
to the DSS position.
5-1
No
5-2
Is the
fault
cleared?
•
•
For DDSS, circuit 8 of the base
unit or PDKU (KCDU does not
support DDSS).
For HDSS, circuit 7 and 8 of
PEKU (PESU does not support
HDSS).
Correct as necessary.
Correct as necessary.
Is the
fault
cleared?
Yes
5-5
Call your technical
support group.
No
END
END
No
Yes
Yes
1883
Test DSS cable with cable continuity
checks in this chapter.
Note
DSS is not available on DK14.
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...