DK40i Installation
Site Requirements
3-2
Strata DK I&M 6/00
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 15 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire ground. (See
Power and Grounding Requirements” on Page 3-4
This eliminates interference from branch circuit motor noise or the like, and to prevent accidental
power-off. To avoid accidental power turn-off, Toshiba recommends that you do
not
use an On/Off
wall switch on this dedicated AC circuit.
For the Strata DK40i, a reserve power source (two customer-supplied 12VDC batteries) may be
connected to the system to serve as a power failure backup.
Clearance and Location
The minimum clearance requirements for the Strata DK40i Base and Expansion KSUs are shown
in
. Refer to
for DK40i KSU mounting instructions.
Consider the following conditions when selecting a location for the KSU(s):
The location
must be
:
♦
Dry and clean
♦
Well ventilated
♦
Well illuminated
♦
Easily accessible
2"
2"
2"
2"
18"
Front View
12.25"
Top View
3.5"
3 Feet
Wall
DK40i
Base KSU
4234
Figure 3-1
DK40i Base KSU Clearance
Requirements
2"
2"
18"
Front View
20"
Top View
3.5"
3 Feet
Wall
2"
DK40i
Base KSU
Expansion
Unit
Base
Expansion
2"
4235
Figure 3-2
DK40i Base KSU and Expansion
KSU Clearance Requirements
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...