Peripheral Installation
Strata CT I&M Manual October 2000
6-37
SMDR Printout Examples
Note
SMDR printout “time of day” and month/day/year (MM/DD/YY) is the same as the
system clock time/date set by the station connected to Port 000. SMDR MM/DD/
YY prints out each time 50 call records are generated and at midnight each day.
Direct Inward System Access (DISA) Exchange Lines
Note
DISA station calls print out as MSS or DISA.
Example 1 – Ring, No Answer DISA Call
Call Sequence A
◆
Outside caller rings Exchange line 003. (Exchange line 003 is programmed as a
DISA line.)
◆
Line 003 returns internal dial tone to caller after one or two ring cycles (5~6
seconds).
◆
Caller does nothing. DH 200 rings but is not answered.
◆
After 32 seconds, call is disconnected.
◆
Printout A prints after disconnect at 4:59.
Printout A: 003 MSS 04:59 00:00;25 00;05
Example 2 – DISA Internal Station Call
Call Sequence B
◆
Outside caller rings Exchange line 003. (Exchange line 003 is programmed as a
DISA line.)
◆
Line 003 returns intercom dial tone to caller after two ring cycles (5~6 seconds).
◆
Caller dials 203.
◆
After 48 seconds from start of call, station 203 answers.
◆
Printout B prints after station 203 answers the call at 4:32.
Note
MSS will not print if the call is answered before the threshold time set in
Program 60-2.
Printout B: 003 MSS 04:32 00:00;48 00;05 203
H
C
Summary of Contents for Strata CT
Page 36: ...Strata CT Configuration 1 22 Strata CT I M Manual October 2000 H C ...
Page 94: ...Strata CT Installation 2 58 Strata CT I M Manual October 2000 H C ...
Page 242: ...Peripheral Installation 6 54 Strata CT I M Manual October 2000 H C ...
Page 258: ...ACD Installation 7 16 Strata CT I M Manual October 2000 H C ...
Page 274: ...Fault Finding 8 16 Strata CT I M Manual October 2000 H C ...
Page 364: ...ISDN Interfaces 10 38 Strata CT I M Manual October 2000 H C ...
Page 370: ...Notes to Users A 6 Strata CT I M Manual October 2000 H C ...