Station
Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
5-3
St
at
io
n
08 QPL Day1
•
Day2
•
Night
QPL for Day1, Day 2 and Night modes.
Possible values: 1~16 (default = 1)
09 Station Name
Enter Station Name to be displayed on this PDNs LCD.
Possible values: Max. 8 characters for CTXR1.0~2.20. Max. 16 chars. for R2.21
and higher. (default = no value)
10 Call Waiting Tone
Select desired waiting tone for Offhook Campon.
Possible values: None (default), Singular or Continuity
11 Dialing Progress
Tone
Select type of Tone to hear after dialing LCR access code
Possible values: Dial Tone (default), Entry Tone or Silence
12 System Call
Forward.
Select the System Call Forward Group number.
Possible values: 0~4 (CTX100), 0~10 (CTX670 Basic), 0~32 (CTX670 Exp.),
(default = 0)
13 Call Pickup
The station privilege to activate Call Pickup.
Possible values: Permitted (default), Group Only or Not Permitted
14 Bearer Capability
ISDN Bearer Capability the PSTN is expecting from non ISDN stations.
3.1kHzAudio (data and speech) or Speech.
Notes
•
Standard telephone type data devices (modems, G3-Fax signals) must be set
for 3.1KHz audio on ISDN lines.
•
The IP-QSIG network does not support 3.1KHz (data and speech), all standard
telephone equipment must be set to ’Speech’ if making calls over IP-QSIGs.
Possible values: 3.1kHzAudio (default) or Speech
15 Display DN
Enter the number to be displayed on the calling telephone that rings this PDN
number. This number is will be overridden by Program 209, 04 (if assigned) and if
the PDN is in a hunt group.
Possible values: Up to 5 ASCII characters (default = no value)
16 Caller Emergency
Service Identification
(CESID)
Enter the E911 Calling Party Information identifier for this station (CESID).
Possible values: Up to 16 digits (default = no value), however CESID should be
10 digits or less for Centralized Automatic Message Accounting
(CAMA) E911 trunk. PRI E911 allows upto 16 digits.
17 Emergency Call
Group
Enter the Emergency call group that this station belongs to.
Possible values: 1~8 (default = 1)
18 Remote CF/DND
Password
Enter password to set or cancel DND or station Call Forward from another CTX
station; or, for Call Forward only, from a external DSIA line.
Possible values: Up to 4 ASCII characters (default = no value)
Note
DND can not be set/canceled remotely from a DISA line.