Strata CTX Programming Guidelines
Step 1: Use Default Auto-programming to Start Up
Strata CTX Programming - Part 1: Getting Started 6/04
1-3
St
ra
ta
CTX
Pr
ogr
am
m
ing
Station PDN Auto-programming
When auto programming recognizes installed station PCBs, it assigns PDNs in numerical order as follows:
•
Auto programming assigns PDNs to station PCB equipment numbers (cabinet, slot, circuit) in
equipment number order. All installed station PCB circuits will be assigned a PDN regardless of the
circuit type, digital (BDKU/BDKS, PDKU) or analog (RSTU).
•
PDN 200 or PDN 2000 (depending on the system size) is assigned to the station circuit having the
lowest equipment number in the system, then the PDN is incremented by one digit and assigned to the
next highest station equipment number and so on. See
Table 1-2
.
•
Program 205 Feature Button Setting –
A Primary DN (PDN) is assigned to
)%
on each digital
telephone according to its equipment number (cabinet, slot, circuit) position. DND is assigned to FB20
on 20-button telephones and is not assigned on 10- and 14-button telephones.
Table 1-2
Auto-Programming for Station Primary Directory Number
CO Line Auto-programming
Table 1-3
shows the CO line PCBs that will be recognized and set in Program 100 during auto-
programming. The default data for CO line Incoming Line Groups (ILG), Outgoing Line Groups (OLG),
and CO line service type is set as shown in
Table 1-4
.
Important!
PCBs must be installed per the rules in the CTX I&M manual, Configuration Chapter,
Worksheet 6 and Worksheet 7.
First digit
CTX100 and CTX670 without BBMS
and BEXS Installed on Processor
CTX670 with BBMS and BEXS
Installed on Processor (First Digit is 2)
2
Primary DNs (3-digits)
200~299 depending on quantity of station
PCBs installed
Primary DNs (4-digit)
2000~2571 depending on qty. of station PCBs
installed
3
Primary DN (3-digits)
300~399 depending on qty. of station
PCBs installed
Table 1-3
Auto-Programming for CO line PCB Recognition (Program 100)
PCB
Code
PCB Name
PCB Circuit Type
Parameter setting
Comments
000
-
No PCB or RRCU
None or Remote cabinets
001
RCOU, RGLU
4 analog Loop or
ground start lines
Direct Incoming Termination (DIT)
lines
005
RCOU+RCOS
8 analog loop start
lines
Direct Incoming Termination (DIT)
lines
006
RDDU
4 analog DID lines
Direct Inward Dial lines
007
RDTU2
16 or 24 digital T1
lines
PCM Highway:
16 or 24
1
T1 Direct Incoming Termination (DIT)
lines
008
RDSU
4 Standard telephone
and for digital
telephone
Standard telephone and DKT2000
and DKT3000 without S-OCA
(DKT3000 limitations: DKT2000, 16
character LCD display on DKT3000,
DKT3000 LCD Feature key does not
function, DKT3014 large screen LCD
does not display).
Summary of Contents for Strata CTX 100-S
Page 20: ......
Page 40: ......
Page 324: ......
Page 445: ...726 Digital Solutions Division June 2004 Part 4 Appendices Digital Business Telephone Systems ...
Page 446: ......
Page 574: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 6 04 ...