Services
Network Busy Lamp Field (BLF) (R1.3 and higher)
9-50
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
Network DSS (R1.3 and higher)
System Availability: Not available with CTX28
When you set up Network DSS, you assign the DSS numbers in the primary CTX first. Then, once you
network the remote CTXs, they will use the DSS numbers set in the primary CTX.
An example of how to set up Network DSS is shown in
Figure 9-3
. In this example, if CTX670-1 is the
primary/host site, then CTX670-2 and CTX100 become remote sites.
Figure 9-3
Network DSS Example
Important!
See steps for programming Network DSS from CTX WinAdmin on the following page.
Remote
(CTX100)
Program 916 - Set
IP Address =
192.168.16.44
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - BLF Server
Port =
3000
Program 670 - Assign
Remote Nodes Data
Program 916 - Set IP
Address =
192.168.17.43
Program 803 - Log. Device
= 500 (DSS), Port 12
Program 801 - BLF Server
Port =
3000
Program 670 - Assign
Primary & Remote Node
Data CTX100
Program 916 - Set IP
Address =
192.168.18.53
Program 803 - Log. Device
= 500 (DSS), Port 12
Program 801 - BLF Server
Port =
3000
Program 670 - Assign
Primary & Remote Node
Data CTX670
QSIG
QSIG
Primary
(CTX670-1)
Remote
(CTX670-2)
6878
LAN / Switch / Hub
LAN / Switch / Hub
LAN / Switch / Hub
IP-Network
IP-Network
Program 656
Node ID: 16
Program 656
Node ID: 17
Program 656
Node ID: 18