Installation
WinCTX Offline Programming CTX R2.21 MH108
3-24
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
4. Select a Region Code: Click the down arrow and highlight a country. The Region Code is the same
country list in Program 915-04.
5. Select the Access Folder: This is where the “default.dat” file will be stored. The empty default folder is
“C:/WINCTX/SM/”.
If you want to use a different folder that contains a default.dat file or create a new “default.dat” file,
click Browse. The Searching Access Folder window displays. Select a folder, then click Set.
To edit an existing “default.dat” file, select the folder that contains the “default.dat” file which should
be edited.
6. Click the Start button. The window title shows “WinCTX is running.”
7. If you click “No,” the second screen displays (see previous page).
If a “default.dat”file exists in the selected folder,
the window (shown right) displays:
¥
Click Yes to load the “default.dat” file into
WinCTX. WinCTX shows “Restoring,” as it loads
the existing default.dat.
If a “default.dat” file is not in the selected folder,
the “Load default.dat?” screen does
not
appear and
WinCTX immediately displays the “WinCTX is
running” screen. You can still connect to WinCTX
to create a new default.dat file in the selected
folder by continuing with the following steps.
8. With WinCTX running, log on to WinAdmin.
•
Enter CTX IP/Name (IP address): 127.0.0.1 or your local PC’s IP address.
•
Enter a Community Name (CTX default is “communityName”).
9. Click the Connect Now button. WinAdmin should connect to WinCTX and operate exactly as if it were
connected to a CTX system.
Note
In the PC Local Area Connection Property Settings, you may need to set the PC Internet Protocol
(TCP/IP) properties to use the following IP address: 192.168.254.251. Subnet mask: 255.255.255.0.
10.Make your offline programming changes from WinAdmin.
11. When you are done programming, select Operation > Data Backup. Click the Back Up button. When
you see “Completed Successfully,” it is done. This will create a new “default.dat” file that contains your
programming changes.
Important!
Data changes will not be stored in the default.dat file unless you backup your data using
WinAdmin.
12.Log out of WinAdmin and then bring up the WinCTX application screen and click the Stop button to
stop WinCTX (see “
Stopping WinCTX
”).
13.To transfer the WinCTX database to a CTX system, locate the “default.dat” file in the folder previously
selected in Step 4.
14.Transfer the “default.dat” file to a SmartMedia card (progdata folder) in the CTX, either locally or
remotely, and then restore the data to the CTX using the system initialization procedure (Program 900
level 1). See
Chapter 10–Operation
, “
900 CTX Restart
.”
7059
Summary of Contents for Strata CTX 100-S
Page 20: ......
Page 40: ......
Page 324: ......
Page 445: ...726 Digital Solutions Division June 2004 Part 4 Appendices Digital Business Telephone Systems ...
Page 446: ......
Page 574: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 6 04 ...