CTX28 Installation
Site Requirements
1-2
Strata CTX28 I&M 3/05
Site Requirements
This section defines the installation site requirements necessary to ensure a proper operating
environment for the CTX28. Also included are grounding requirements.
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 1.5 amps. The AC
outlet is recommended to be dedicated and unswitched. (See
This eliminates interference from branch circuit motor noise or the like, and to prevent accidental
power-off. To avoid accidental power turn-off, Toshiba recommends that you do
not
use an On/Off
wall switch on this dedicated AC circuit.
For the Strata CTX28, a reserve power source (HPFB-6) may be connected to the system to serve
as a power failure backup (
Clearance and Location
The minimum clearance requirements for the
Strata CTX28 Base cabinet is shown in
. Refer to
for
CTX28 KSU mounting instructions.
Consider the following conditions when selecting
a location for the KSU(s):
The location
must be
:
•
Dry and clean
•
Well ventilated
•
Well illuminated
•
Easily accessible
The location
must not be
:
•
Subject to extreme heat or cold
•
Subject to corrosive fumes, dust, or other
airborne contaminants
•
Subject to excessive vibration
•
Next to television, radio, office automation, or
high frequency equipment
If reserve power (HPFB-6) is to be installed for
the Strata CTX28, the batteries will require a
well-ventilated location close to the CHSU28A.
Figure 1-1
CTX28 Base KSU Clearance
Requirements