background image

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
          
 
 
 
 

Part Number Description 

GWY-02 

Gateway Protocol Converter, RS232/RS485, Powered from PLC, includes 50cm 
cable for connection to T1 programming port. 

GWY-08 

Gateway Protocol Converter, RS485/RS485, Requires 24 Vdc Power. 

CNV-01-02-2-0 

RS232 to RS422/RS485 Converter, 2 wire / 4 wire. 

SC-Y-019A-00 

Y Cable, Connects Gateway to T1 and PC for downloading Gateway Program. 

SC-Y-019A-00 

Y Cable, Connects Gateway to T2 and PC for downloading Gateway Program. 

SC-G-019A-00 

Cable, Connects Gateway to T1 programming port, 2m. 

SC-G-019B-00 

Cable, Connects Gateway to T2 programming port, 2m. 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

Page 4 

ADJUSTABLE  SPEED DRIVES   MOTORS   CONTROLS   UPS   INSTRUMENTATION   PLC  DCS 

 

INTERNATIONAL  CORPORATION 

13131 West Little York Rd   Houston, TX 77041 
Ph: 713-466-0277        Fax:  713-466-8773 
US:  800-231-1412    Canada: 800-872-2192    Mexico:  001-800-527-1204 
Email: 

plc@tic.toshiba.com

     Website:  

www.tic.toshiba.com

                                   

 

Dimensions

 

 

Mounting is via Din Rail or Through Hole 

Order Information

Available Through: 

Rev 2003.5.1 

Summary of Contents for T1-40 PLC

Page 1: ...th Toshiba T1 40 PLC Temperature Controllers Motor Protection Relays CAN WE TALK Everyone Always Wants to Know What Everyone Else is Doing Adjustable Speed Drives Don t Let Anyone Work Alone Higher Level Controller Computer DCS PLC Programmable Controllers ...

Page 2: ...s used to map the registers between the other devices controllers to registers in the Toshiba PLC Toshiba PLC as Master on Modus Network Toshiba PLC as Slaves on Modus Network Toshiba PLC to Other PLC Connection Page 2 Description Applications Operator Interface Station Adjustable Speed Drive Modbus Temperature Controller Modbus Toshiba Protocol XY Protocol We Can Talk Now Toshiba T2 PLC Toshiba T...

Page 3: ...starting with holding register 400001 3 Holding registers in the PID controller are written into the data registers of the T1 starting at D0 D0 D2 It is also possible to control the priority and frequency of the data transfer using the Gateway setup software Page 3 Power Supply 24 VDC 5 50 ma MAX No Fuse inside 5 VDC 5 FROM PLC 120 ma MAX Communication Two ports as follows Com 1 RS232C RS485 Com 2...

Page 4: ...Connects Gateway to T2 and PC for downloading Gateway Program SC G 019A 00 Cable Connects Gateway to T1 programming port 2m SC G 019B 00 Cable Connects Gateway to T2 programming port 2m Page 4 ADJUSTABLE SPEED DRIVES MOTORS CONTROLS UPS INSTRUMENTATION PLC DCS INTERNATIONAL CORPORATION 13131 West Little York Rd Houston TX 77041 Ph 713 466 0277 Fax 713 466 8773 US 800 231 1412 Canada 800 872 2192 M...

Reviews: