TB9051FTG
Ver.1.1 2019-03-14
38 / 49
10.2. Power supply monitoring function
Table 10.2 Electrical characteristics of power supply monitoring function
Test condition unless otherwise specified, VBAT = 4.5 to 28 V,VCC = 4.5
to
5.5 V, Ta = -40 to 125°C
Parameter Symbol
Pin
name
Test condition
MIN
TYP.
MAX
Unit
VBAT
undervoltage
detection voltage
VBATRSTL VBAT Figure
7.6.1-1 3.5
3.75 4.0 V
VBAT
undervoltage
release voltage
VBATRSTH VBAT Figure
7.6.1-1 4.0
4.25 4.5 V
Hysteresis width of
VBAT
undervoltage
detection
VBATRSTHY VBAT
Figure
7.6.1-1
0.1 0.50 1
V
VBAT
undervoltage
detection filter
TVBAT_uv
VBAT Figure
7.6.1-2 1.0 2.0 3.5
μ
s
VCC undervoltage
detection voltage
VCCHL VCC Figure
7.6.2-1 3.3 3.5 3.7 V
Hysteresis width of
VCC undervoltage
detection
VCCHLHYS VCC Figure
7.6.2-1 0.1 0.20 0.3 V
VCC undervoltage
detection filter
TVCC_uv VCC Figure
7.6.2-2 1.56 2.5 4.2 ms
VCC undervoltage
detection filter (at
release)
TVCC_uv2 VCC Figure
7.6.2-2 0 100 167
μ
s
VCC undervoltage
POR detection
voltage
VCCRHL VCC Figure
7.6.2-1 2.85
3.07 3.25 V
Hysteresis width of
VCC undervoltage
POR detection
VCCRHLHYS VCC
Figure
7.6.2-1 0.1
0.20 0.3 V
VCC undervoltage
POR detection
filter
TVCC_por VCC Figure
7.6.2-3 5.0
13.0
20.0
μ
s
VCC high voltage
detection voltage
VCCHLH VCC Figure
7.6.3-1 5.57
5.80 5.97 V
Hysteresis width of
VCC high voltage
detection
VCCHHLHYS VCC
Figure
7.6.3-1
10 30 70 mV
VCC high voltage
detection filter
TVCC_up VCC Figure
7.6.3-2 1.56 2.5 4.2 ms
VCC high voltage
detection filter (at
released)
TVCC_up2 VCC Figure
7.6.3-2 0 100 167
μ
s