 Page 8 

 

Repair and maintenance to electrical components shall include initial safety checks and component 
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be 
connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately 
but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be 
reported to the owner of the equipment so all parties are advised.  
Initial safety checks shall include:  
That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; 
That there no live electrical components and wiring are exposed while charging, recovering or purging 
the system; That there is continuity of earth bonding.

 8)Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct 
    specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in 
    doubt consult the manufacturer's technical department for assistance. The following checks shall be 
    applied to installations using flammable refrigerants: 
    The charge size is in accordance with the room size within which the refrigerant containing parts are 
    installed; 
    The ventilation machinery and outlets are operating adequately and are not obstructed; 
    If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence 
    of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that 
    are illegible shall be corrected; 

Refrigeration pipe or components are installed in a position where they are unlikely to be exposed 

1)During repairs to sealed components, all electrical supplies shall be disconnected from the equipment 
being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an 
electrical supply to equipment during servicing, then a permanently operating form of leak detection 
shall be located at the most critical point to warn of a potentially hazardous situation. 
2)Particular attention shall be paid to the following to ensure that by working on electrical components, 
the casing is not altered in such a way that the level of protection is affected. This shall include damage 
to cables, excessive number of connections, terminals not made to original specification, damage to 
seals, incorrect fitting of glands, etc.  Ensure that apparatus is mounted securely. Ensure that seals or 
sealing materials have not degraded such that they no longer serve the purpose of preventing the 
ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's 
specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection 
equipment. Intrinsically safe components do not have to be isolated prior to working on them.

9)Checks to electrical devices

7.Repairs to sealed components 

Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will 
not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe 
components are the only types that can be worked on while live in the presence of a flammable 
atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts 
specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere 
from a leak.

8.Repair to intrinsically safe components 

to any substance which may corrode refrigerant containing components, unless the components are 
constructed of materials which are inherently resistant to  being corroded or are suitably protected 
against being so corroded.

Summary of Contents for TDDP2012ES2C

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference ...

Page 2: ...aintenance Table of Contents Control Panel Features 12 Other features 13 Removing the collected water 14 Clean the bucket 16 Troubleshooting Tips 17 Clean the air filter 16 Store the unit 16 Identification of parts 11 Design Notice 11 Positioning the unit 11 Troubleshooting Tips ...

Page 3: ... the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during operation Do not use the unit in small spaces Do not put in places where water may splash onto the unit Place the unit on a level sturdy section of the floor Do not cover the intake or exhaust openings w...

Page 4: ...en damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate unit with...

Page 5: ...n of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehumidifier in the European countries the following information must be followed The municipality has established collection systems where electronic waste can be disposed of at least free of charge to ...

Page 6: ...enance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appliance shall be stored in a room without continuously operating open flames for example an operating gas appliance and ignition sources for example an operating electric heater Appliance should be installed operated and...

Page 7: ...mable material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 5 Presence of fire extingu...

Page 8: ... supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation 2 Particular attention shall be paid to the following to en...

Page 9: ...tions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not...

Page 10: ...ng order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in...

Page 11: ...ns see the Remote Controller Instruction packed with the unit for details Design Notice In order to ensure the optimal performance of our products the design specifications of the unit are subject to change without prior notice Preparation 20cm or more 40cm or more 20cm or more 20cm or more 40cm or more This unit is designed to operate with a working environment between 5 C 41 F and 32 C 90 F and ...

Page 12: ...quel to or less than 0 C 32 F Comfort button On some models Press to activate the comfort dehumidifying operation At Comfort dehumidifying mode the unit will automatically control room humidity in a comfortable range 45 55 according to the room temperature The humidity setting function will be invalid Note On this operation the unit can not be set humidity level Continue CONT button On some models...

Page 13: ...ket is ready to be emptied or when the bucket is removed or not replaced in the proper position Auto Defrost When forst builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears proper position When the setting humidity is reached the unit will be shut off automatically For some models the fan motor will continue to run for 30 secon...

Page 14: ...inage facility by attaching the pump drain out with a pump drain hose od Φ1 4 supplied 3 Pump draining on some models water outlet Note If the pump hose drops when you remove the bucket you must reinstall the pump hose properly to the unit before replace the bucket into the unit Pump hose drops Reinstall pump hose properly Drain hose AdaptorA Note Make sure the connection is tight and there is no ...

Page 15: ... the pump draining feature When the pump draining feature is not being used remove the pump drain hose from the outlet Press the pump drain hose outlet in and take the pump drain hose out from it Make sure do not let the water in the pump hose drip to the floor Note Make sure the connection is tight and there is no leak Lead the water hose to the floor drain or a suitable drainage facility the dra...

Page 16: ...ter at least every 30 days or more often if necessary Care and cleaning of the dehumidifier WARNING Turn the dehumidifier off and remove the plug from the wall outlet before cleaning When not using the unit for long time periods After turning off the unit wait one day before emptying the bucket Clean the main unit bucket and air filter Wrap the cord and bundle it with the band Cover the unit with ...

Page 17: ... dehumidifier has Auto defrost feature Did not allow enough time to remove the moisture Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off wate...

Page 18: ......

Page 19: ......

Page 20: ... and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...

Page 21: ... 290 3 颜色 黑白 4 注意 排版时注意页码数字都是靠外面的 以便翻阅 5 装订 备注 1 基准说明书只适合K平台所有常规机型 2 基准说明书为单英文版本 不含型号及商标 也无制造商信息 请业务根据所 销售国家或者区域的法规要求 使用对应的官方语言版本 增加型号及其它 法规要求信息 重新申请订单编码说明书 3 基准说明书的显示标贴为K平台全功能 包含了目前已有的所有图标和功能按键及其 操作说明 4 后面的选配页面标明了对应的不同机型 可燃冷媒与非可燃冷媒 下要修改的内容 ...

Page 22: ...当机型为非可燃冷媒机型时 请进行以下变更 删除Pg6 Pg10 WARNING for Using R32 R290 Refrigerant 内容 ...

Reviews: