TRANSPORTATION AND INSTALLATION MANUAL
2.3.4 Precautions for Direct Installation
When two (2) or more controllers are used, it is necessary to provide a clearance of 50
mm or more in the horizontal direction and a clearance of 100 mm or more in the
upward direction between the controllers.
!
CAUTION
• Provide a ventilation space at the side of the controller so that the air vent
holes are not blocked. The space equal to the length of the legs should be
kept below the lower surface.
Failure to do so could cause the cooling performance to drop or to faults.
• DO NOT stack the controllers. DO NOT place any object on top of them.
MO T O R
EN C
TP
I N PU T
O UT PU T
EXT I / O
T S 1 0 0 0
T O S H I B A M A C H I N E
PO WER
AC I N
5AT
R o b o t C o n t r o l l e r
CO M1
HO ST
H AN D
T C PR G
2 4 V 0 V A B F G
T P
d isconnect
Fig. 2.16 Controller ventilation space
50 mm or more
50 mm or more
11mm
100 mm or more