MAINTENANCE MANUAL
85
STE 85357
!
CAUTION
• The air tube is a consumable item. Check the condition during periodic inspection. If any
damage is found, replace it.
• Please note that Fig. 3.3 shows a piping example and does not warrant damage to the air
tube and its accessories.
3.1.3
Check of Cable Clamp Tightening
Using a wrench, make sure that the clamps securing the cable are not loose. There
are two clamps, one on the arm 2 side and the other on the base side. If they are
loose, apply Loctite (low adhesive force) and tighten them. When checking the
tightened clamps, check the one on the base side first. By checking the tightness of
the clamp on the base side first, the twist of the cable can be adjusted slightly on the
arm 2 side. Make sure to tighten the clamps in the posture as shown in the figure
below. If the clamps are tightened while the arm is bent, the cable cannot be
installed correctly.
Fig. 3.4 Cable clamp inspection locations (THL500, THL600, THL700)
Make sure that the clamp and the nut
are securely tightened. If they are
loose, fix the clamp in position and
then tighten the nut. Be careful not to
twist the cable at this time.
Make sure that the clamp is securely
tightened. If it is loose, tighten the clamp.