Chapter 15 Interrupt Controller
15-30
15.4.18 Interrupt Request Polarity Control Register (IRPOL)
0xF518
31
16
FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC
[31] [30] [29] [28] [27] [26] [25] [24] [23] [22] [21] [20] [19] [18] [17] [16]
R/W
:
Type
0x0000
: Initial value
15
14
13
12
11
10 9 8 7 6 5 4 3 2 1 0
FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC FPC
[15] [14] [13] [12] [11] [10] [9] [8] [7] [6] [5] [4] [3] [2] [1] [0]
R/W
:
Type
0x0000
: Initial value
Bits Mnemonic Field
Name
Explanation
31:0 FPC[31:0]
Flag Polarity
Control
Flag Polarity Control[31:0] (Initial value: 0x0000_0000, R/W)
These bits specify the polarity of the flag bit that generated the interrupt. An
interrupt request is generated when the XOR of the FPC bit and the flag bit is “1.”
Flag bit (PF)
FPC bit
Interrupt request
0
0
No
0
1
Yes
1
0
Yes
1
1
No
Figure 15.4.18 Interrupt Request Polarity Control Register
15.4.19 Interrupt Request Control Register (IRRCNT)
0xF51C
31
16
Reserved
:
Type
:
Initial
value
15
3
2
1
0
Reserved
OD
EXTPOL
INTPOL
R/W
R/W
R/W
:
Type
0
1
1
:
Initial
value
Bits Mnemonic Field
Name
Explanation
31:3
⎯
Reserved
⎯
2 OD
External Interrupt
OD Control
External Interrupt Open Drain Control (Initial value: 0, R/W)
This bit specifies whether to make the external interrupt signal (IRC[2]*) an open
drain pin or not.
0: Open drain (reset)
1: Totem pole
1 EXTPOL
External Interrupt
Request Polarity
Control
External Interrupt Polarity Control (Initial value: 1, R/W)
This bit specifies the polarity of external interrupt requests.
0: Do not reverse polarity of interrupt requests.
1: Reverse polarity of interrupt requests
0 INTPOL
Internal Interrupt
Request Polarity
Control
Internal Interrupt Polarity Control (Initial value: 1, R/W)
This bit specifies the polarity of internal interrupt requests.
0: Do not reverse polarity of interrupt requests.
1: Reverse polarity of interrupt requests
Figure 15.4.19 Interrupt Request Control Register
Summary of Contents for TMPR4925
Page 1: ...64 Bit TX System RISC TX49 Family TMPR4925 Rev 3 0 ...
Page 4: ......
Page 15: ...Handling Precautions ...
Page 16: ......
Page 18: ...1 Using Toshiba Semiconductors Safely 1 2 ...
Page 40: ...3 General Safety Precautions and Usage Considerations 3 18 ...
Page 42: ...4 Precautions and Usage Considerations 4 2 ...
Page 43: ...TMPR4925 ...
Page 44: ......
Page 54: ...Chapter 1 Features 1 8 ...
Page 58: ...Chapter 2 Block Diagram 2 4 ...
Page 88: ...Chapter 4 Address Mapping 4 12 ...
Page 226: ...Chapter 8 DMA Controller 8 58 ...
Page 260: ...Chapter 9 SDRAM Controller 9 34 ...
Page 480: ...Chapter 15 Interrupt Controller 15 32 ...
Page 554: ...Chapter 19 Real Time Clock RTC 19 8 ...
Page 555: ...Chapter 20 Removed 20 1 20 Removed ...
Page 556: ...Chapter 20 Removed 20 2 ...
Page 564: ...Chapter 21 Extended EJTAG Interface 21 8 ...
Page 580: ...Chapter 22 Electrical Characteristics 22 16 ...
Page 588: ...Chapter 24 Usage Notes 24 2 ...