TOSHIBA
5.3
Voltage Matching
5.3.1
Proportional Output Voltage (Standard)
This feature allows programming the inverter to deliver an output voltage that
is an exact percentage of the input voltage. The output voltage can range from
0% to 100% of the input voltage. The word "proportional" comes from the fact
that if the input voltage level rises or falls during operation, the output voltage
follows in direct proportion. The following examples illustrate this feature.
Function Function
Adjustment
Factory
Error
Ref.
No.
Name
Display
Range
Unit
Set
Message
Page
Output voltage adjustment
0 to 100 (Option: 0 to 120)
%
100
8-27
2ND
4
0: Non DBR
Dynamic brake resisitor
1: DBR, No OLr detection (*1 pg 6-10)
0
8-27
2: DBR, OLr detection (*1 pg 6-10)
Auto deceleration on the
0: On
0
8-27
: Pb=0
1: Off
Proportional Output
Voltage (
P.Out
)
set to 87%
Input
260V
230V
200V
Voltage
Time
Output
226V
200V
174V
Voltage
Time
M
Motor rated at 230V
Motor rated at 200V
60 80Hz
200V
230V
60 80Hz
Example 1
Example 2
M
Power supply 230V
Power supply 230V
G2+
G2+
G2+
Function Parameters
5 - 3
Note:
For ease of identification the inverters are listed in horsepower.
However the real determining factor, when sizing an inverter, is the rated
current capability. Therefore, the user must be aware that a reduction in
motor voltage means higher currents will be required.
Be sure that the inverter's rated current capability is always
greater than the total current required.