TOSHIBA
6 - 2
6.2
Operating Panel Keys and Functions (cont'd)
OFF
STOP
PRG
AUTO
SETUP
CLEAR
RESET
READ
WRITE
Keys and Functions
*
See Section 2.2 Note #11 for
Emergency Stop.
Key disables
RUN or STOP commands until either the AUTO or MANUAL
key is pressed. Display reads "OFF". Motor coasts to a stop if key is pressed
twice while drive is running.
*
Disables manual control and turns the manual control LED off; drive will accept
commands from terminal strip connector or computer input only.
This key is used to scroll through the system parameters (see page 7-2), read
data from within the group or setup parameters, write data changes into the
non-volatile memory. System status information is available while drive is
running.
Key used to scroll through the parameter groups and returns to frequency
setting if in any other mode.
When data changes have been made in error, this key will allow user to clear
data back to data = 0 (if allowed). Also resets trips, or returns to frequency
mode.
This key stops the drive in manual mode. The manual mode stop can be
programmed to coast or decelerate to a stop. Will cause the drive to trip and
motor coasts to a stop in auto mode.
*
Allows access to setup parameters only and will automatically return to
frequency mode after all parameters have been stepped through.