9.7
PATTERN FREQUENCY GROUP PARAMETERS (cont'd)
PATTERN #6 RUN TIME (ITEM 16) - Use this function to set the run time of the preset
speed frequency SR6.
PATTERN #6 DRIVE CHARACTERISTIC (ITEM 17) - Use this function to select the type
of run for preset speed frequency #SR6. The selection can be a forward or reverse run,
using either ACC/DEC #1 or ACC/DEC #2.
PATTERN #7 RUN TIME (ITEM 18) - Use this function to set the run time of the preset
speed frequency SR7 (Firespeed Override Frequency).
PATTERN #7 DRIVE CHARACTERISTIC (ITEM 19) - Use this function to select the type
of run for preset speed frequency #SR7 (Firespeed Override Frequency). The selection
can be a forward or reverse run, using either ACC/DEC #1 or ACC/DEC #2.
JOG FREQUENCY (ITEM 20) - Use this function to set the frequency at which the
inverter will operate while in the jog mode. Used for moving in small increments when
precise positioning of motor driven equipment is required.
JOG STOP SELECT (ITEM 21) - Use this function to select between three methods of
stopping during a jog run.
START-UP FREQUENCY (ITEM 22) - Use this function to set the frequency at which
the inverter will begin operating. In the manual control mode the frequency display will
change as the "up" and "down" keys are pressed. However, an actual output does not
occur until the start-up frequency is reached. In the terminal input mode the display will
remain at zero until the start-up frequency is reached. This function along with the
voltage boost function, allows the user to obtain an optimum boost level. See the
illustrations below.
RUN FREQUENCY (ITEM 23) - Use this function to select a frequency to initiate inverter
run/stop control.
0
100%
Hz
F-St
0
30%
100%
Voltage
boost
Start-Up Frequency with Voltage Boost
Fmax
Start-Up Frequency
FREQUENCY
OUTPUT VOLTAGE
FREQUENCY SETTING SIGNAL
OUTPUT FREQUENCY
Fstart