E6581090
H-4
8
■
Example of call-up of trip information
Item
displayed
Key
operated
LED
display
Communication
No.
Description
QR
Status monitor mode (The code blinks if a trip occurs.)
The motor coasts and comes to a stop (coast stop).
Parameter
setting
mode
CWJ
The first basic parameter "History (
CW
)" is displayed.
Direction of
rotation
HTH
FE01
The direction of rotation at the occurrence of a trip is displayed.
(
H
: forward run,
T
: reverse run)
Operation
frequency
command
H
FE02
The operation frequency command value at the occurrence of a
trip is displayed.
Load
current
E
FE03
The inverter output current at the occurrence of a trip is
displayed. (Default setting: unit %)
Input
voltage
[
FE04
The inverter input (DC) voltage at the occurrence of a trip is
displayed. (Default setting: unit %)
Output
voltage
R
FE05
The inverter output voltage at the occurrence of a trip is
displayed. (Default setting: unit %)
Torque
current
Y
FE20
The torque current at the occurrence of a trip is displayed in %.
PI feedback
F
FE22
The PI feedback value at the occurrence of a trip is displayed.
(Unit: frequency)
Inverter
load factor
N
FE27
The inverter load factor at the occurrence of a trip is displayed
in %.
Output
power
J
FE30
The output power of the inverter at the occurrence of a trip is
displayed in %.
Operation
frequency
Z
FE00
The operation frequency at the occurrence of a trip is displayed.
Input
terminal
C!!
FE06
The ON/OFF status of each of the control signal input terminals
(F, R, S1, S2 and VI/S3) at the occurrence of a trip is displayed
in bits.
ON :
OFF :
_
Output
terminal
Q
FE07
The ON/OFF status of each of the control signal output
terminals (FM/OUT and FL) at the occurrence of a trip is
displayed in bits.
ON :
OFF :
_
(Continued overleaf)
▲
Output terminal FL
Output terminal
FM/OUT
Q
Note 2
▲
C!!
Input terminal VI/S3
Input terminal S2
Input terminal F
Input terminal R
Input terminal
S1
MON
Note 1
MON
▲
▲
▲
▲
▲
▲
▲
▲
▲