E6581090
H-5
8
(Continued)
Item
displayed
Key
operated
LED
display
Communication
No.
Description
CPU1
version
X
FE08
The version of the CPU1 is displayed.
CPU2
version
XY
FE73
The version of the CPU2 is displayed.
Memory
version
XG
FE09
The version of the memory mounted is displayed.
Past trip 1
QR
⇔
FE10
Past trip 1 (displayed alternately at 0.5-sec. intervals)
Past trip 2
QJ
⇔
FE11
Past trip 2 (displayed alternately at 0.5-sec. intervals)
Past trip 3
QR
⇔
FE12
Past trip 3 (displayed alternately at 0.5-sec. intervals)
Past trip 4
PGTT
⇔
FE13
Past trip 4 (displayed alternately at 0.5-sec. intervals)
Cumulative
operation
time
VQ
FE14
Cumulative operation time (0.01 corresponds to 1 hours.)
Default
display
mode
QR
Status monitor mode (The LED blanks if trip occurs.)
Note 1: Press the or key to change items displayed in the status monitor mode.
Note 2: The FL output is held OFF in case of a trip, since the operation status immediately before the
occurrence of the tip is retained by the status monitor output terminal board retention function.
Note 3: Failure trip information is cleared if the power is turned off or the inverter is reset. Therefore,
the operation status is displayed and all failure information except for the cause of the failure
is cleared, even if the trip information retention function is activated.
▲
▲
▲
▲
▲
▲
▲
MON
▲
▲
▼