E6581090
L-1
12
12. Specifications
12.1
Models and their standard specifications
■
Standard specifications
Item
Specification
Input voltage
3-phase 200V
Applicable motor (kW)
0.1
0.2
0.4
0.75
1.5
2.2
Type
VFNC1
Form
2001P
2002P
2004P
2007P
2015P
2022P
Capacity (kVA) Note 1)
0.3
0.6
1.0
1.6
2.9
3.9
Rated output current (A)
Note 2)
0.7
1.4
2.4
4.0
7.5
10.0
Rated output voltage
Note 3)
3-phase 200V to 240V
Ra
tin
g
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
3-phase 200V to 240V - 50/60Hz
Allowable fluctuation
25/V10%, -15% Note 4), frequency
±
5%
Po
w
er
su
pp
ly
Ampere Interrupt
Capacity (A) AIC
1000
1000
1000
1000
5000
5000
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
Self-cooling
Forced air-cooled
Color
Munsel 5Y8/0.5
Charge lamp
LED indicating the charge status of the capacitor in the main circuit
Built-in filter
-
Item
Specification
Input voltage
1-phase 200V
Applicable motor (kW)
0.1
0.2
0.4
0.75
1.5
2.2
Type
VFNC1S
Form
-
2002P
2004P
2007P
2015P
2022P
Capacity (kVA) Note 1)
-
0.6
1.0
1.6
2.9
3.9
Rated output current (A)
Note 2)
-
1.4
2.4
4.0
7.5
10.0
Rated output voltage
Note 3)
3-phase 200V to 240V
Ra
tin
g
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
1-phase 200V to 240V - 50/60Hz
Allowable fluctuation
V10%, -15% Note 4), frequency
±
5%
Po
w
er
su
pp
ly
Ampere Interrupt
Capacity (A) AIC
-
1000
1000
1000
5000
5000
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
-
Self-cooling
Forced air-cooled
Color
Munsel 5Y8/0.5
Charge lamp
LED indicating the charge status of the capacitor in the main circuit
Built-in filter
-