E6581090
L-2
12
Item
Specification
Input voltage
1-phase 100V
Applicable motor (kW)
0.1
0.2
0.4
0.75
1.5
2.2
Type
VFNC1S
Form
1001P
1002P
1004P
1007P
-
-
Capacity (kVA) Note 1)
0.3
0.6
1.0
1.6
-
-
Rated output current (A)
Note 2)
0.7
1.4
2.4
4.0
-
-
Rated output voltage
Note 3)
3-phase 200V to 230V
Ra
tin
g
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
1-phase 100V to 115V - 50/60Hz
Allowable fluctuation
V10%, -15% Note 4), frequency
±
5%
Po
w
er
su
pp
ly
Ampere Interrupt
Capacity (A) AIC
1000
1000
1000
1000
-
-
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
Self-cooling
Forced
air-cooled
-
-
Color
Munsel 5Y8/0.5
Charge lamp
LED indicating the charge status of the capacitor in the main circuit
Built-in filter
-
Item
Specification
Input voltage
1-phase 200V (built-in EM1 noise filter)
Applicable motor (kW)
0.1
0.2
0.4
0.75
1.5
2.2
Type
VFNC1S
Form
-
2002PL
2004PL
2007PL
2015PL
2022PL
Capacity (kVA) Note 1)
-
0.5
0.9
1.6
2.9
4.1
Rated output current (A)
Note 2)
-
1.2
2.3
4.0
7.5
10.7
Rated output voltage
Note 3)
3-phase 200V to 240V
Ra
tin
g
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
1-phase 200V to 240V - 50/60Hz
Allowable fluctuation
V10%, -15% Note 4), frequency
±
5%
Po
w
er
su
pp
ly
Ampere Interrupt
Capacity (A) AIC
-
1000
1000
1000
5000
5000
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
-
Self-cooling
Forced air-cooled
Color
Munsel 5Y8/0.5
Charge lamp
None
Built-in filter
EMC noise filter (Class B)
Note)
1. Capacity is calculated at 220V for the 200V models.
2. Indicates rated output current setting when the PWM carrier frequency (parameter
H
) is 4kHz or
less.
If the PWM carrier frequency setting is fixed above 4 kHz, the rated current needs to be reduced. If the
PWM carrier frequency is set above 4 kHz, it could fall automatically if an over-current flaws during
acceleration or for any other reason, depending on the amount of current that flows.
The default setting of the PWN carrier frequency is 12kHz.
3. Maximum output voltage is the same as the input voltage.
With regard to 100V models, the output voltage may decrease about 10 to 20 % if motor load is applied.
When operating VFNC1 in conjunction with general purpose motor (200V), it is necessary to reduce the
motor load.
4.
±
10% when the inverter is used continuously (load of 100%).