E6581595
F-60
6
6.18.5 Changing the initial display of the panel
: Initial panel display selection
: Initial extension panel display selection
Function
This parameter specifies display format while power is ON.
Changing the display format while power is ON
When the power is ON, the standard monitor mode displays the output frequency (default setting) in the
format of "
" or "
". This format can be changed to any other monitor display format by setting
. This new format, however, will not display an assigned prefix such as
or
. When the power is
ON, the display of the extension panel is set at
.
When the power is ON, the main panel and the extension panel can be set to display differently.
[Parameter setting]
Title
Function
Adjustment range
Default setting
Initial panel display selection
0: Output frequency (Hz/free unit)
1: Output current (%/A)
2: Frequency command value (Hz/free unit)
3 to 17: -
18: Arbitrary code from communication
19 to 51: -
52: Frequency command value /
output frequency (Hz/free unit)
0
Initial extension panel display
selection
0
For details on /
=
, see the Communications Function Instruction Manual.
6.18.6 Changing display of the status monitor
-
: Status monitor 1 to 6
Change monitor display items in the status monitor mode.
Refer to chapter 8 for details.