E6581595
G-3
7
Connecting
1)
For logic input a
2)
For connection (sink logic) via transistor output
About programmable controllers and interfaces
Supply the power for logic input terminal from external to P24 terminal (external 24Vdc input terminal) in case of
controlling the inverter by using an open collector output of programmable controller.
CC
Input terminal
Operates by short circuiting between
the input terminal and CC (common).
Use for forward rotation, reverse
rotation, and multi-stage speed.
Inverter
Relay a-contact
With sink settings
Control by connecting the input terminal
and CC (common) to the output (non-logic
switch) of the programmable controller. Use
for forward rotation, reverse rotation, and
multi-stage speed. Use a 5 mA transistor
that operates at 24 V dc.
Inverter
Programmable controller
CC
Input terminal