E6581595
C-13
3
3.4
Meter setting and adjustment
: Meter selection
: Meter adjustment gain
Function
Output of 0 - 1mAdc, 0 (4) - 20mAdc, 0 - 10vdc can be selected for the output signal from the FM
terminal, depending no the
setting. Adjust the scale at
.
Use an ammeter with a full-scale 0 - 1mAdc meter.
The
(analog output bias) needs to be adjusted if output is 4 - 20mAdc.
[Parameter setting]
Title Function
Adjustment
range
Supposition output at
f
sl
=
17
Default setting
Meter
selection
0: Output frequency
1: Output current
2: Frequency command value
3: Input voltage (DC detection)
4: Output voltage (command value)
5 to 11: -
12: Stator frequency
13: VI input value
14: -
15: Fixed output 1 (output current 100%
equivalent)
16: Fixed output 2 (output current 50%
equivalent)
17: Fixed output 3 (other than the
output current)
18: RS485 communication data
19: For adjustments (
set value is
displayed.)
20 to 22: -
Maximum frequency (
)
-
Maximum frequency (
fh
)
1.5x rated voltage
1.5x rated voltage
-
Maximum frequency (
fh
)
Maximum input value
-
-
-
-
Maximum value (100.0%)
-
-
0
Meter
adjustment
gain
- -
-