[Methods of setting automatic acceleration/deceleration]
Operation panel
action
LED display
Operation
Displays the output frequency.
(When standard monitor display selection
=
[Output frequency])
The first basic parameter “
” (history function) is displayed.
Turn the setting dial to the right to change the parameter to
.
Parameter values can be read by pressing the center of the setting
dial.
Turn the setting dial to the right to change the parameter to
1
or
.
Press the center of the setting dial to save the changed parameter.
and the parameter are displayed alternately.
Assigning the forced deceleration command (function number 122, 123) to any logic input terminal, it can be
changed automatic deceleration by compulsion.
5.3.2
Manually setting acceleration/deceleration time
:
Acceleration time 1
:
Deceleration time 1
Function
1) For acceleration time 1
programs the time that it takes for the inverter output frequency to go
from 0.0Hz to maximum frequency
.
2) For deceleration time 1
programs the time that it takes for the inverter output frequency to go
from maximum frequency
to 0.0Hz.
Output frequency (Hz)
Time [sec]
O
(Manual)
[Parameter setting]
Title Function
Adjustment range
Default setting
Acceleration time 1
0.0-3000 s
10.0
Deceleration time 1
0.0-3000 s
10.0
Note: When the acceleration/deceleration time is set to 0.0 seconds, the inverter accelerates and decelerates
0.05 seconds.